APPENDIX I. MODEL NUMBER NOMENCLAT URE
Unit Heat Type
48 Gas Heat
Packaged
Rooftop
Series/Model
HC Standard Efficiency
Heat Size
D - Low Heat
E - Medium Heat
F - High Heat
L - Low NOx, Low Heat
M - Low NOx, Medium Heat
N - Low NOx, High Heat
S - Stainless Steel, Low Heat
R - Stainless Steel, Medium Heat
T - Stainless Steel, High Heat
(Low NOx models include - Stainless Steel HX
Refrigeration Systems Options
A - Standard One-Stage Cooling Models
B - Standard One-Stage Cooling Models
with Humidi-MiZer (04 - 07 Models only)
D - Two-Stage Cooling Models, 08-16
E - Two-Stage Cooling Models, 08-16
with Al/Cu Condenser Coils and
Humidi-MiZer
Cooling Tons
04 - 3 Ton 08 - 7.5 Ton
05 - 4 Ton 09 - 8.5 Ton
06 - 5 Ton 12 - 12.5 Ton
07 - 6 Ton 14 - 12.5 Ton
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
2
Sensor
F = RA Smoke Detector and CO
2
Sensor
G = SA Smoke Detector and CO
2
Sensor
H = RA + SA Smoke Detector and CO
2
Sensor
Indoor Fan Options 3,4, 5 Ton Models Only*
0 = Electric (Direct) Drive X13 Motor
2 = Medium Static Option - Belt drive
3 = High Static Option - Belt Drive
Indoor Fan Options 6 - 12.5 Ton Models Only*
1 = Standard Static Option - Belt Drive
2 = Medium Static Option - Belt Drive
3 = High Static Option - Belt Drive
C = High Static option w/High Efficiency Motor - Belt
Drive (Size 14 only)
*See price page details for specific Humidi-MiZer models.
Packaging and Seismic Compliant
0 = Standard
1 = LTL
3 = CA Seismic Compliant
4= LTL and CA Seismic Compliant Label
Electrical Options
A = None
C = Non-Fused Disconnect
D = Thru-the-Base Connections
F = Non-Fused Disconnect and Thru-the-Base Connections
G = 2-Speed Indoor Fan (VFD) Controller
J = 2-Speed Fan Controller (VFD) and Non-Fused Disconnect
K = 2-Speed Fan Controller (VFD) and Thru-the-Base Connections
M = 2-Speed Fan Controller (VFD) with Non-Fused Disconnect and
Thru-the-Base Connections
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels, Unpowered Convenience Outlet
5 = Hinged Panels, Powered Convenience Outlet
Intake / Exhaust Options
A = None
B = Temperature Economizer w/ Barometric Relief
F = Enthalpy Economizer w/ Barometric Relief
K = 2 - Position Damper
U = Temp Ultra Low Leak Economizer with Barometric Relief
W = Enthalpy Ultra Low Leak Economizer with Barometric Relief
Base Unit Controls
0 = Base Electromechanical Controls
1 = PremierLink Controller
2 = RTU-Open Multi-Protocol Controller
6 = Electromechanical w/ 2-Speed Fan and W7220 Econo Controller
Design Revision
- = Factory Assigned
Voltage
1 = 575/3/60 5 = 208-230/3/60
3 = 208-230/1/60 6 = 460/3/60
Coil Options for Round Tube/Plate Fin Condenser Coil Models
Only (outdoor-indoor-hailguard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-Coat Al/Cu - Al/Cu
D = E-Coat Al/Cu - E-Coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu -Al/Cu - Louvered Hail Guards
N = Precoat Al/Cu - Al/Cu - Louvered Hail Guards
P = E-Coat Al/Cu - Al/Cu - Louvered Hail Guards
Q = E-Coat Al/Cu - E-Coat Al/Cu - Louvered Hail Guards
R = Cu/Cu - Al/Cu - Louvered Hail Guards
S = Cu/Cu - Cu/Cu - Louvered Hail Guards
Coil Options for All Aluminum - Novation Condenser Coil Models
Only (outdoor-indoor-hailguard)
G = Al/Al - Al/Cu
H = Al/Al - Cu/Cu
J = Al/Al - E-Coat Al/Cu
K = E-Coat Al/Al - Al/Cu - Al/Cu
L = E-Coat Al/Al - E-Coat Al/Cu
T = Al/Al - Al/Cu - Louvered Hail Guards
U = Al/Al - Cu/Cu - Louvered Hail Guards
V = Al/Al - E-Coat Al/Cu - Louvered Hail Guards
W= E-Coat Al/Al - Al/Cu - Louvered Hail Guards
X = E-Coat Al/Al - E-Coat Al/Cu - Louvered Hail Guards
H
Note: On single phase (-1 voltage code) models,
the following are NOT available as a factory
installed option (FIOP):
- Humidi-MiZer
- Coated Coils or Cu Fin Coils
- Louvered Hail Guards
- Economizer or 2 Position Damper
- Powered 115 VAC Convenience Outlet
C12096
Fig. 75 -- Model Number Nomenclature
48HC