EasyManua.ls Logo

Carrier 48HC 04-28 User Manual

Carrier 48HC 04-28
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 0453480236-01 Printed in U.S.A. Form 48/50HC-05T Pg 1 7-19 Replaces: 48/50HC-04T
Controls, Start-Up, Operation and
Troubleshooting
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 3
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
BASIC CONTROL USAGE . . . . . . . . . . . . . . . . . . . . . 4
ComfortLink Control . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Scrolling Marquee . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Accessory Navigator™ Display . . . . . . . . . . . . . . . . . 4
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
System Pilot™ and Touch Pilot™ Devices . . . . . . . . 6
CCN Tables and Display . . . . . . . . . . . . . . . . . . . . . . . 6
Force Hierarchy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Generic Status Display Table . . . . . . . . . . . . . . . . . . . 6
Conventions Used in This Manual . . . . . . . . . . . . . . . 7
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Unit Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Compressor Mounting . . . . . . . . . . . . . . . . . . . . . . . . 7
Refrigerant Service Ports . . . . . . . . . . . . . . . . . . . . . . 7
Crankcase Heater(s) . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Compressor Rotation . . . . . . . . . . . . . . . . . . . . . . . . . 7
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Internal Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Evaporator Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
48/50HC 04-06 UNITS WITH DIRECT DRIVE FANS
BELT DRIVE UNITS
BELT DRIVE UNITS WITH A VFD
Condenser Fans and Motors . . . . . . . . . . . . . . . . . . . 8
Return-Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Outdoor-Air Inlet Screens . . . . . . . . . . . . . . . . . . . . . 8
Accessory Installation . . . . . . . . . . . . . . . . . . . . . . . . 8
Orifice Change (48HC) . . . . . . . . . . . . . . . . . . . . . . . . 8
Gas Heat (48HC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Units with EnergyX® System . . . . . . . . . . . . . . . . . . 10
BASE UNIT EVAPORATOR FAN
START-UP CHECK LIST
•ERV TEST MODE
ERV CONFIGURATION
ERV WITH ECONOMIZER ADDITIONAL
CONFIGURATIONS
ADJUSTING ERV OPTIONS
CONTROLS QUICK SET-UP . . . . . . . . . . . . . . . . . . . 11
Control Set Point and Configuration Log . . . . . . . . 11
Thermostat Control . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Space Temperature Sensor Control - Direct
Wired (T-55 or T-56 or T-59) . . . . . . . . . . . . . . . . . 11
T-58 Communicating Room Sensor . . . . . . . . . . . . 12
CCN Linkage Control . . . . . . . . . . . . . . . . . . . . . . . . 12
System Pilot™ - Communication Space Sensor . . 12
Thermidistat Control . . . . . . . . . . . . . . . . . . . . . . . . . 12
Space Humidistat Control . . . . . . . . . . . . . . . . . . . . .12
Relative Humidity Sensor Control . . . . . . . . . . . . . .12
CCN Communication . . . . . . . . . . . . . . . . . . . . . . . . .12
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
ECONOMIZER
POWER EXHAUST
ELECTRIC HEAT
FIRE SHUTDOWN
OUTDOOR ENTHALPY
•IAQ SWITCH
IAQ SENSOR
OAQ SENSOR
FAN STATUS
FILTER STATUS
Programming Operating Schedules . . . . . . . . . . . . .13
SERVICE TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Independent Outputs . . . . . . . . . . . . . . . . . . . . . . . . .15
Fan Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Cooling Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Humidi-MiZer® Test . . . . . . . . . . . . . . . . . . . . . . . . . .15
Heating Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
THIRD PARTY CONTROL . . . . . . . . . . . . . . . . . . . . .16
Cooling/Heating Control . . . . . . . . . . . . . . . . . . . . . .16
Dehumidification Control . . . . . . . . . . . . . . . . . . . . .16
Remote Occupancy . . . . . . . . . . . . . . . . . . . . . . . . . .16
Fire Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Alarm Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Economizer Damper Control . . . . . . . . . . . . . . . . . .16
CONTROLS OPERATION . . . . . . . . . . . . . . . . . . . . .16
Display Configuration . . . . . . . . . . . . . . . . . . . . . . . .16
Unit Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . .16
THERMOSTAT CONTROL TYPE (T.CTL)
Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
General Operation . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Temperature Setpoint Determination . . . . . . . . . . . .18
Occupancy Determination . . . . . . . . . . . . . . . . . . . .18
LEVEL 1 PRIORITY
LEVEL 2 PRIORITY
LEVEL 3 PRIORITY
INDOOR FAN OPERATION
CONSTANT VOLUME (CV) UNITS (FTYP = 1-SPEED)
Cooling Operation . . . . . . . . . . . . . . . . . . . . . . . . . . .20
COOLING MODE CONTROL
STAGING CONTROL
COMPRESSOR CONTROL
OUTDOOR FAN CONTROL
Heating Operation . . . . . . . . . . . . . . . . . . . . . . . . . . .21
HEATING MODE CONTROL
SUPPLY-AIR TEMPERATURE SENSOR (SAT)
STAGING CONTROL
HEAT RELAY CONTROL
Economizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
48/50HC 04-28
Single Package Rooftop Units
with ComfortLink Controls Version 3.X and Puron
(R-410A) Refrigerant

Table of Contents

Other manuals for Carrier 48HC 04-28

Question and Answer IconNeed help?

Do you have a question about the Carrier 48HC 04-28 and is the answer not in the manual?

Carrier 48HC 04-28 Specifications

General IconGeneral
BrandCarrier
Model48HC 04-28
CategoryAir Conditioner
LanguageEnglish

Summary

SAFETY CONSIDERATIONS

General Safety Information and Warnings

Covers general safety precautions, warnings for electrical shock, cuts, and fire hazards.

GENERAL

Unit Overview and ComfortLink Control System

Provides a general description of the rooftop unit and the ComfortLink control system.

BASIC CONTROL USAGE

User Interface Devices

Describes the Scrolling Marquee and Accessory Navigator display devices.

Operation

Navigating the Control Display Interface

Explains how to navigate through the control system menus using the display interface.

System Pilot™ and Touch Pilot™ Devices

CCN Communication Interface and Tables

Details the CCN interface, tables, and communication setup for devices.

Force Hierarchy

Priority Levels for Forcing Variables

Explains the hierarchy of control forces and their priority levels.

Generic Status Display Table

Custom Table Creation and Upload Process

Describes how to create and upload custom status display tables.

Conventions Used in This Manual

Path Name Convention and Symbols Usage

Outlines the conventions used for path names and symbols in the manual.

START-UP

Unit Preparation and Component Checks

Details the necessary steps for unit preparation and checks before start-up.

Accessory Installation

Installing Various Field-Installed Accessories

Provides guidance on installing field-installed accessories.

Gas Heat (48HC)

Gas Pressure Verification and Settings

Details the procedures for verifying gas pressure and making adjustments.

Units with EnergyX® System

ERV Start-Up Checklist and Configuration

Covers the start-up checklist and configuration for ERV units.

CONTROLS QUICK SET-UP

System Configuration and Setup Guide

Provides a quick guide for setting up and configuring the unit's controls.

Control Set Point and Configuration Log

Emphasizes the importance of logging control set points and configuration changes.

T-58 Communicating Room Sensor

CCN Linkage and System Pilot™ Interface Setup

Details the setup for T-58 sensors, CCN linkage, and System Pilot interface.

Accessories

Configuration for Economizer, Power Exhaust, Electric Heat, and IAQ

Outlines configuration settings for common field-installed accessories.

Programming Operating Schedules

Setting Occupied and Unoccupied Time Schedules

Explains how to program time schedules for unit operation.

SERVICE TEST

Testing Independent Outputs, Fans, and Cooling Operations

Describes how to use Service Test to verify operation of various unit components.

Humidi-MiZer™ and Heating Tests

Details the Service Test procedures for Humidi-MiZer and heating operations.

THIRD PARTY CONTROL

Cooling/Heating and Dehumidification Control Integration

Discusses integrating third-party controls for HVAC functions.

CONTROLS OPERATION

Display and Unit Configuration Settings

Covers configuring display settings and unit parameters.

Start-Up Delay and Control Types

Explains start-up delay settings and unit control types.

Modes

System, HVAC, and Indoor Fan Mode Definitions

Defines the various system, HVAC, and indoor fan modes of operation.

General Operation

Thermostat and Space Sensor Control Logic

Explains the logic for thermostat and space sensor-based unit control.

Temperature Setpoint Determination

Occupancy and Setpoint Adjustments

Details how setpoints are determined based on occupancy and adjustments.

INDOOR FAN OPERATION

Fan Type and Speed Control Configuration

Covers configuring the indoor fan type and speed settings.

Staged Air Volume (SAV) Units

SAV Fan Speed Control Parameters and Curves

Explains SAV fan speed control parameters and performance curves.

STAGING CONTROL

Staging Logic for Thermostat and Space Sensor Control

Details the staging logic based on thermostat and space sensor inputs.

COMPRESSOR CONTROL

Compressor Availability and Protection Logic

Explains compressor control, availability, and protection measures.

Heating Operation

Heating Mode Control Logic and Resource Management

Outlines the logic for heating mode operation and resource utilization.

HEATING MODE CONTROL

Thermostat and Space Sensor Heating Control Logic

Explains heating mode control based on thermostat or space sensor.

SUPPLY-AIR TEMPERATURE SENSOR (SAT)

SAT Heat Mode Sensing Configuration Options

Details the configuration for SAT sensing in heating mode.

Integrated Gas Controller (IGC)

IGC Operation and Safety Logic

Explains the function and operation of the Integrated Gas Controller.

Economizer

Economizer Installation and Fault Detection/Diagnostics

Covers economizer installation and its fault detection diagnostics.

Economizer Fault Detection and Diagnostics (continued)

Actuator Stuck or Jammed Testing Procedures

Details the testing procedures for identifying stuck or jammed economizer actuators.

ECONOMIZER ACTUATOR COMMUNICATION

Digital vs. Analog Actuator Communication Protocols

Explains the communication methods for the economizer actuator.

Indoor Air Quality (IAQ)

IAQ Sensor Configuration and DCV Operation Modes

Covers IAQ sensor setup and Demand Controlled Ventilation modes.

Optional Humidi-MiZer® Dehumidification System

Humidi-MiZer™ System Overview and Configuration Options

Provides an overview of the Humidi-MiZer system and its configuration.

REHEAT MODES

Reheat Mode Operation and Circuit Control Logic

Explains the operation of different reheat modes and circuit control.

REHEAT CONTROL

Reheat Mode Operation and Diagnostic Help Information

Details reheat mode operation and provides diagnostic help.

Temperature Compensated Start

Temperature Compensated Start Logic and Setup Procedures

Explains the logic and setup for temperature compensated start.

Carrier Comfort Network® (CCN) Configuration

CCN Settings: Address, Baud Rate, Broadcasts, and Schedules

Covers various CCN configuration settings.

Demand Limit

Demand Limit Control Configuration and Network Integration

Explains demand limit control setup and network integration.

Alarm Handling

Alarm Types, Indications, and Reset Methods

Covers alarm types, how they are indicated, and reset procedures.

EnergyX® Units

ERV System Overview and Operation Details

Provides an overview of the EnergyX ERV system and its operational details.

COMMUNICATION

ERV Communication Points and Status Monitoring

Details the communication points the ERV uses and monitors.

3 to 25 Ton Modulating ERV

Modulating ERV Operation Overview and Control Flow Chart

Provides an overview of modulating ERV operation and its control flow.

OCCUPANCY

ERV Occupancy Determination Logic and Modes

Explains how ERV occupancy is determined and its operating modes.

MODES OF OPERATION

ERV Operating Modes: Off, Test, Free Cooling, OA Tempering, Defrost, DCV

Details the various operating modes for the ERV unit.

TROUBLESHOOTING

Complete Unit Stoppage Causes and Resolution Steps

Identifies common causes of unit stoppage and their resolution.

Alarms and Alerts

Viewing, Clearing, and Understanding Unit Alarms

Explains how to view, clear, and understand unit alarms and alerts.

DIAGNOSTIC ALARM CODES AND POSSIBLE CAUSES

Compressor Fault Codes and Troubleshooting Procedures

Lists compressor fault codes and their possible causes and troubleshooting steps.

Circuit Temperature Thermistor Failure Alerts

Details alerts related to circuit temperature thermistor failures.

Alert Code T110 and T111 — Circuit Loss of Charge

Loss of Charge Alerts and Related Troubleshooting

Explains alerts related to circuit loss of charge.

Alert Code T175 — Loss of communication with VFD

VFD Communication Loss Alert and Troubleshooting

Covers alerts for loss of communication with the VFD.

Alert Code T179 — Loss of Communication with the Economizer Control Board

ECB Communication Loss Alert and Diagnosis

Details alerts for loss of communication with the ECB.

Alarm Code A404 — Fire Shutdown

Fire Shutdown Alarm Logic and Configuration

Details the logic and configuration for fire shutdown alarms.

Alert Code T414

Economizer Damper Actuator Alerts and Calibration Procedures

Covers various economizer damper actuator alerts and calibration.

Table 14 — ComfortLink Alarm Codes

Compressor Safety Trip and Turnoff Alerts

Lists compressor safety trip and turnoff alarm codes.

Table 14 — ComfortLink Alarm Codes (cont)

Circuit Loss of Charge and High Discharge Pressure Alerts

Details alarms for circuit loss of charge and high discharge pressure.

Control Module Communication

MBB and ECB LED Status Indicators and Communication Failures

Explains LED indicators and communication failure troubleshooting.

Cooling Troubleshooting

Cooling Service Analysis and Problem Resolution

Offers a guide for analyzing and resolving cooling system issues.

Humidi-MiZer™ Troubleshooting

Humidi-MiZer Service Analysis and Problem Resolution

Provides a guide for analyzing and resolving Humidi-MiZer system issues.

Economizer Troubleshooting

Economizer Service Analysis and Testing Procedures

Details economizer service analysis and testing methods.

Table 18 — Economizer Service Analysis

Economizer Damper Operation and Troubleshooting Scenarios

Analyzes economizer damper operation and common troubleshooting scenarios.

Heating Troubleshooting

Gas Heating Service Analysis and Problem Resolution

Provides analysis and resolution for gas heating issues.

Phase Loss Protection

Phase Reversal and Phase Loss Protection Mechanisms

Explains the phase loss and reversal protection features.

Thermistor Troubleshooting

Thermistor Identification and Check Procedures

Covers thermistor identification and checking procedures.

THERMISTOR/TEMPERATURE SENSOR CHECK

Sensor Trim Procedures for Calibration

Details procedures for trimming and calibrating temperature sensors.

Transducer Troubleshooting

Suction Pressure Transducer Characteristics and Verification

Explains suction pressure transducer characteristics and verification.

Forcing Inputs and Outputs

Forcing Variables and Procedures for Testing

Describes how to force input and output variables for testing.

Troubleshooting Units Equipped with EnergyX® System

Complete ERV Stoppage Causes and Resolution Steps

Identifies causes of complete ERV stoppage and resolution steps.

CHECK ALARMS

ERV Alarm Codes and Diagnostic Information

Covers ERV alarm codes and diagnostic information.

Check Diagnostic LEDs

EXCB and UPC LED Indicators and Flash Code Diagnostics

Explains EXCB and UPC LED indicators and flash code diagnostics.

Communication Failures

UPC Communication Failures and Troubleshooting

Details troubleshooting for UPC communication failures.

On-Board Pressure Transducers

Pressure Transducer Characteristics and Verification

Explains the characteristics and verification of on-board pressure transducers.

MAJOR SYSTEM COMPONENTS

General Overview of Control System Components

Provides a general overview of major system components.

Main Base Board (MBB)

MBB Overview and Connection Points

Details the MBB overview and its connection points.

Economizer Control Board (ECB)

ECB Overview and Connection Points

Provides an overview of the ECB and its connection points.

Integrated Gas Control (IGC) Board

IGC Board Overview and Connection Points

Details the IGC board overview and its connection points.

Communication Interface Board (CIB)

CIB Overview and Connection Points

Explains the CIB overview and its connection points.

Central Terminal Board (CTB)

CTB Overview and Connection Points

Details the CTB overview and its connection points.

Scrolling Marquee Display

Marquee Display Functionality and Navigation

Describes the functionality and navigation of the scrolling marquee display.

Accessory Navigator™ Display

Navigator Display Functionality and Connection

Explains the functionality and connection of the navigator display.

Carrier Comfort Network® (CCN) Interface

CCN Wiring and Installation Guidelines

Provides guidelines for wiring and installing the CCN interface.

Protective Devices

Compressor and Fan Motor Protection Mechanisms

Covers protection mechanisms for compressor and fan motors.

Field-Installed Accessories

Space Temperature Sensors (T-55, T-56, T-58)

Details installation and wiring for space temperature sensors.

IAQ/OAQ Sensors, Smoke Detectors, and Filter/Fan Status Accessories

Covers installation of IAQ/OAQ sensors, smoke detectors, and filter/fan status accessories.

ENTHALPY SENSORS

Enthalpy Sensor Installation and Configuration

Explains the installation and configuration of enthalpy sensors.

RETURN/SUPPLY AIR TEMPERATURE SENSOR

SAT/RAT Sensor Installation and Configuration

Details installation and configuration for SAT/RAT sensors.

SPACE HUMIDISTAT

Space Humidistat Installation and Configuration

Covers the installation and configuration of the space humidistat.

Units with EnergyX® System

ERV System Overview and Operation Details

Provides an overview of the EnergyX ERV system and its operational details.

ENERGYX CONTROL BOARD (EXCB)

EXCB Overview and Input/Output Connections

Details the EXCB overview and its input/output connections.

Universal Protocol Converter (UPC)

UPC Overview, Setup, and LCD Text Messages

Explains the UPC overview, setup procedures, and LCD text messages.

EnergyX Options and Accessories

Economizer Damper, Frost Protection, Wheel Motor Status

Details options and accessories like economizer damper and frost protection.

SERVICE AND MAINTENANCE

EnergyX System Cleaning Procedures

Provides procedures for cleaning the EnergyX system.

EnergyX System Cleaning

Wheel and Segment Cleaning Procedures

Details the cleaning process for the ERV wheel and segments.

FILTERS

Filter Cleaning or Replacement Schedule

Describes the schedule for cleaning or replacing filters.

EnergyX Wheel Drive Adjustment

Wheel Drive Adjustment Procedures and Belt Inspection

Details wheel drive adjustment and belt inspection.

EnergyX Wheel Air Seal Adjustment

Air Seal Adjustment Procedures for Wheel Cassettes

Explains how to adjust air seals on wheel cassettes.

WHOLE WHEEL REMOVAL / INSTALLATION (25-46 INCH WHEELS)

Wheel Removal and Installation Procedures for 25-46 Inch Wheels

Provides detailed steps for removing and installing 25-46 inch wheels.

Outside Air and Exhaust Air Hood Removal

Hood Removal Procedures for Outside and Exhaust Air

Details the procedures for removing outside and exhaust air hoods.

Outside Air Motorized Damper Removal

Damper Access Panel and Motor Connector Removal

Explains how to remove the outside air motorized damper.

Outside Air and Exhaust Fan Replacement

Fan Removal Procedures for Outside and Exhaust Fans

Details the procedures for replacing outside and exhaust fans.

EXHAUST FAN REMOVAL

Exhaust Fan Access Panel and Component Disconnection

Explains how to remove the exhaust fan assembly.

APPENDIX A — LOCAL DISPLAY AND CCN TABLES

Table A — Mode — Run Status

Provides a table of run status modes and their parameters.

APPENDIX A — LOCAL DISPLAY AND CCN TABLES (cont)

Table B — Mode — Service Test

Provides a table of modes for Service Test.

APPENDIX A — LOCAL DISPLAY AND CCN TABLES (cont)

Table E — Mode — Inputs

Lists input modes and their parameters.

Table F — Mode — Outputs

Lists output modes and their parameters.

APPENDIX A — LOCAL DISPLAY AND CCN TABLES (cont)

Table G — Mode — Set Points

Provides a table of set point modes and their parameters.

Table H — Mode — Configuration

Lists configuration modes and their parameters.

APPENDIX A — LOCAL DISPLAY AND CCN TABLES (cont)

Table I — Mode — Time Clock

Provides a table of time clock modes and their parameters.

APPENDIX A — LOCAL DISPLAY AND CCN TABLES (cont)

Table K — Mode — Operating Modes

Lists operating modes and their parameters.

APPENDIX A — LOCAL DISPLAY AND CCN TABLES (cont)

Table L — Mode — Alarms

Lists alarm modes and their parameters.

APPENDIX B — CONTROL MODES WITH HUMIDI-MIZER SYSTEM AND ECONOMIZER

Table M — Single-Circuit Units

Table showing control modes for single-circuit units.

Table N — Dual Circuit Units 1-Stage Y1 and 2-Stage Y1

Table showing control modes for dual-circuit units.

Table O — Dual Circuit Units Digital

Table showing control modes for dual-circuit units with digital control.

APPENDIX C — VARIABLE FREQUENCY DRIVE (VFD)

VFD Overview, Connections, and Parameters

Provides an overview of VFDs, their connections, and parameters.

APPENDIX C — VARIABLE FREQUENCY DRIVE (VFD) (cont)

VFD Parameters Configured by Factory or Keypad

Lists VFD parameters configured by factory or keypad.

VFD Parameters Hard Coded by ComfortLink Controls

Lists VFD parameters hard-coded by ComfortLink controls.

VFD Parameters Configurable Through ComfortLink Controls

Lists VFD parameters configurable via ComfortLink controls.

APPENDIX C — VARIABLE FREQUENCY DRIVE (VFD) (cont)

VFD Motor Default Configurations

Provides default configurations for VFD motors based on unit size and voltage.

APPENDIX C — VARIABLE FREQUENCY DRIVE (VFD) (cont)

VFD Diagnostics and Fault Reporting

Explains VFD diagnostics, fault reporting, and LED indicators.

Table V — Fault Codes

VFD Fault Codes and Corrective Actions

Lists VFD fault codes and their descriptions/corrective actions.

Table W — Alarm Codes

VFD Alarm Codes and Corrective Actions

Lists VFD alarm codes and their descriptions/corrective actions.

APPENDIX C — VARIABLE FREQUENCY DRIVE (VFD) (cont)

CONTROL SET POINT AND CONFIGURATION LOG

Provides a template for logging control set points and configurations.

APPENDIX D — ENERGYX® EXHAUST FAN PERFORMANCE

3 Ton SRT Unit ERV Supply and Exhaust Fan Performance Curves

Presents performance curves for 3 Ton SRT ERV supply and exhaust fans.

APPENDIX D — ENERGYX® EXHAUST FAN PERFORMANCE (cont)

4 and 5 Ton SRT Unit ERV Supply and Exhaust Fan Performance Curves

Shows performance curves for 4 and 5 Ton SRT ERV supply and exhaust fans.

APPENDIX D — ENERGYX® EXHAUST FAN PERFORMANCE (cont)

6 Ton SRT Unit ERV Supply and Exhaust Fan Performance Curves

Presents performance curves for 6 Ton SRT ERV supply and exhaust fans.

7.5, 8.5 and 10 Ton SRT Unit ERV Supply and Exhaust Fan Performance Curves

Shows performance curves for 7.5, 8.5, and 10 Ton SRT ERV fans.

APPENDIX D — ENERGYX® EXHAUST FAN PERFORMANCE (cont)

12.5 Ton SRT Unit ERV Supply and Exhaust Fan Performance Curves

Displays performance curves for 12.5 Ton SRT ERV supply and exhaust fans.

15 and 17.5 Ton Unit ERV Supply Exhaust Fan Performance Curves

Presents performance curves for 15 and 17.5 Ton ERV supply and exhaust fans.

APPENDIX D — ENERGYX® EXHAUST FAN PERFORMANCE (cont)

20 and 25 Ton Unit ERV Supply Exhaust Fan Performance Curves

Shows performance curves for 20 and 25 Ton ERV supply and exhaust fans.

ENERGYX® UNIT START-UP CHECKLIST

Pre-Start-Up Checks and Verification Procedures

Details the pre-start-up checks for the EnergyX unit.

Start-Up Procedures and Electrical Checks

Covers start-up procedures, including electrical and temperature checks.