EasyManua.ls Logo

Carrier 58TN0B User Manual

Carrier 58TN0B
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
l
Installation, Start–Up, Operating and
Service and Maintenance Instructions
NOTE: Read the entire instruction manual before starting the
installation.
TABLE OF CONTENTS
Table 1 – Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CODES AND STANDARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCE-
DURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Table 2 – Minimum Free Area Required for Each Combustion Air
opening of Duct to Outdoors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 3 – Minimum Space Volumes for 100% Combustion, Ventila-
tion, and Dilution from Indoors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 4 – Opening Dimensions - In. (mm). . . . . . . . . . . . . . . . . . . . 10
FILTER ARRANGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table 5 Optional Filter Media Pressure Drop (Clean) Versus Airflow
- in. w.c. (Pa). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 6 – Optional Filter Media Pressure Drop (Clean) Versus Face
Velocity- in. w.c. (Pa). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 7 – Air Filter Selection and Duct Sizing - In. (mm) . . . . . . . . 14
AIR DUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
GAS PIPING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 8 – Maximum Capacity of Pipe . . . . . . . . . . . . . . . . . . . . . . . 16
ELECTRICAL CONNECTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table 9 – Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
TEMPERATURE SENSOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
VENTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 10 – Combined Appliance Maximum Input Rating
in Thousands of BTUh per Hour . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 11 – Minimum Allowable Input Rating of
Space-Heating Appliance in Thousands of BTUh per Hour . . . . . . 22
Table 12 – Recommended Minimum Vent Height Per Furnace and
Vent Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 13 – Air Delivery - CFM (with Filter)* . . . . . . . . . . . . . . . . . 26
FURNACE CONTROL PROGRAMMING
AND NAVIGATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 14 – System Status Display Codes . . . . . . . . . . . . . . . . . . . . . 29
Table 15 – Main Menu Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
SERVICE LABEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
START-UP, ADJUSTMENT, AND SAFETY CHECK . . . . . . . . . . . 31
Table 16 – Test Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 17 – Altitude Derate Multiplier for U.S.A.. . . . . . . . . . . . . . . 33
Table 18 – Gas Rate (CU ft./hr.). . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 19 Orifice Size and Manifold Pressure (in. w.c.) for Gas Input
Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 20 Orifice Size and Manifold Pressure (in. w.c.) for Gas Input
Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
SERVICE AND MAINTENANCE PROCEDURES. . . . . . . . . . . . . . 39
ELECTRICAL CONTROLS AND WIRING . . . . . . . . . . . . . . . . . . . 39
CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 21 – Filter Size Information - In. (mm) . . . . . . . . . . . . . . . . . 40
SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
PARTS REPLACEMENT INFORMATION GUIDE . . . . . . . . . . . . . 50
EXAMPLE OF MODEL NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . 50
TRAINING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
To learn more about this appliance and installation via a mobile device,
go to https://carrier.hvacpartners.com/NFC or use the QR code below. To
access airflow tables or troubleshooting guide on your mobile device go
to mlctraining.com/training/techdocs/95/ or use the QR code below.
A230297
Most states in the USA and jurisdictions in Canada have laws that
require the use of Carbon Monoxide (CO) alarms with fuel burning
products. Examples of fuel burning products are furnaces, boilers, space
heaters, generators, water heaters, stoves/ranges, clothes dryers,
fireplaces, incinerators, automobiles, and other internal combustion
engines. Even if there are no laws in your jurisdiction requiring a CO
Alarm, it’s highly recommended that whenever any fuel burning product
is used in or around the home or business that the dwelling be equipped
with a CO Alarm(s). The Consumer Product Safety Commission
recommends the use of CO Alarm(s). The CO Alarm(s) must be
installed, operated, and maintained according to the CO Alarm
manufacturer’s instructions. For more information about Carbon
Monoxide, local laws, or to purchase a CO Alarm online, please visit the
following website. https://www.kidde.com.
A200103
Portions of the text and tables are reprinted from NFPA 54/ANSI Z223.1E, with permission of National Fire Protection Association, Quincy, MA 02269 and American
Gas Association, Washington DC 20001. This reprinted material is not the complete and official position of the NFPA or ANSI on the referenced subject, which is
represented only by the standard in its entirety.
58TN0B/58TN1B
80% AFUE, Two-Stage, Variable–Speed
4–Way Multipoise, Non-Condensing Gas Furnace
WARNING
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury and/or
death.
Carbon Monoxide (CO) is a colorless, odorless, and tasteless poisonous
gas that can be fatal when inhaled. Follow all installation, maintenance,
and service instructions. See additional information below regarding
the installation of a CO Alarm.
Use of the AHRI Certified TM Mark indicates
a manufacturer’s participationin the program.
For verification of certification for individual
products, go to www.ahridirectory.org .
Question and Answer IconNeed help?

Do you have a question about the Carrier 58TN0B and is the answer not in the manual?

Carrier 58TN0B Specifications

General IconGeneral
Model58TN0B
CategoryFurnace
Efficiency80% AFUE
StagesSingle-stage
Fuel TypeNatural Gas
Warranty10-year parts limited warranty
TypeGas

Summary

SAFETY CONSIDERATIONS

INTRODUCTION

CODES AND STANDARDS

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCEDURE

LOCATION

LOCATION RELATIVE TO COOLING EQUIPMENT

Specifies placement of cooling coil relative to furnace.

AIR FOR COMBUSTION AND VENTILATION

Details requirements for combustion and ventilation air supply.

INSTALLATION

Bottom Return Air Inlet

Procedure for removing the bottom closure panel.

Side Return Air Inlet

Guidelines for using side return air inlets.

Leveling Legs (If Desired)

Information on installing leveling legs.

Downflow Installation

Instructions for downflow furnace installation.

FILTER ARRANGEMENT

AIR DUCTS

GAS PIPING

ELECTRICAL CONNECTIONS

TEMPERATURE SENSOR

VENTING

FURNACE CONTROL PROGRAMMING AND NAVIGATION

On-Board Control Method

Details using the furnace's built-in control panel for settings.

NFC and Supported App Method

Using NFC for parameter adjustment and diagnostics via mobile device.

Bluetooth® Module

Information on activating the Bluetooth module for wireless connectivity.

SERVICE LABEL

START-UP, ADJUSTMENT, AND SAFETY CHECK

Adjustments

Procedures for adjusting furnace settings like gas input and temperature rise.

Check Safety Controls

Steps to verify the proper function of safety controls like limit switches.

WIRING DIAGRAM

SERVICE AND MAINTENANCE PROCEDURES

CARE AND MAINTENANCE

General guidelines for routine furnace care and maintenance.

Cleaning and/or Replacing Air Filter

Instructions for cleaning or replacing the air filter.

Blower Motor and Wheel Maintenance

Steps for cleaning the blower motor and wheel.

Cleaning Heat Exchanger

Procedure for cleaning the heat exchanger components.

TROUBLESHOOTING

PARTS REPLACEMENT INFORMATION GUIDE

Related product manuals