VENTING
NOTE:
Planning
for
the
venting
system
should
be
done
in
conjunction
with
planning
for
the
ductwork,
drainage,
and
furnace
accessories,
such
as air
cleaners
and
humidifiers.
Begin
assembling
the
venting
system
AFTER
the
furnace
is
set
in
place
in
the
required
orientation.
Venting
for
this
furnace
shail
follow
all
Local codes
for
Category
IV
venting
systems.
This
furnace
is
CSA
approved
for
venting
with
PVC/ABS
DWV
venting
systems.
This
furnace
is
also
CSA
approved
for
venting
with
M&G
DuraVent®
venting
systems.
PolyPro®
polypropylene
NOTE:
THESE
INSTRUCTIONS
DO
NOT
CONTAIN
DETAILED
INSTALLATION
INSTRUCTIONS
FOR
POLYPROPYLENE
VENTING
SYSTEMS.
Refer
to
the
polypropylene
venting
system
manufacturer’s
installation
instructions
for
the
polypropylene
venting
system
installation.
NOTE:
When
using
polypropylene
venting
systems,
all
venting
materials
used,
including
the
vent
terminations,
must
be
from
the
same
manufacturer.
Special
Venting
Requirements
for
Installations
in
Canada
Installation
in
Canada
must
conform
to
the
requirements
of
CSA
B149
code.
Vent
systems
must
be
composed
of
pipe,
fittings,
cements,
and
primers
listed
to
ULC
$636.
The
special
vent
fittings,
accessory
concentric
vent
termination
kits
and
accessory
external
drain
trap
available
from
the
furnace
manufacturer
have
been
certified
to
ULC
S636
for
use
with
those
Royal
Pipe
and
IPEX
PVC
vent
components
which
have
been
certified
to
this
standard.
In
Canada,
the
primer
and
cement
must
be of
the
same
manufacturer
as
the
vent
system
GVS-65
Primer
(Purple)
for
Royal
Pipe
or
IPEX
System
636,
PVC/CPVC
Primer,
Purple
Violet
for
Flue
Gas
Venting
and
GVS-65
PVC
Solvent
Cement
for
Royal
Pipe
or
IPEX
System
636(;)t,
PVC
Cement
for
Flue
Gas
Venting,
rated
Class
ITA,
65
deg
C.
must
be
used
with
this
venting
system
-
do
not
mix
primers
and
cements
from
one
manufacturer
with
a
vent
system
from
a
different
manufacturer.
Follow
the
manufacturer’s
instructions
in
the
use
of
primer
and
cement
and
never
use
primer
or
cement
beyond
its
expiration
date.
The
safe
operation,
as
defined
by
ULC
$636,
of
the
vent
system
is
based
on
following
these
installation
instructions,
the
vent
system
manufacturer’s
installation
instructions,
and
proper
use
of
primer
and
cement.
All
fire
stop
and
roof
flashing
used
with
this
system
must
be
UL
listed
material.
Acceptability
under
Canadian
standard
CAN/CSA
B149
is
dependent
upon
full
compliance
with
all
installation
instructions.
Under
this
standard,
it
is
recommended
that
the
vent
system
be
checked
once
a
year
by
qualified
service
personnel.
The
authority
having
jurisdiction
(gas
inspection
authority,
municipal
building
department,
fire
department,
etc.)
should
be
consulted
before
installation
to
determine
the
need
to
obtain
a
permit.
*IPEX
System
636™
is
a
trademark
of
IPEX
Inc.
Consignes
spéciales
pour
Vinstallation
de
ventilation
au
Canada
Vinstallation
faite au
Canada
doit
se
conformer
aux
exigences
du
code
CSA
B149-2010.
Ce
systéme
de
ventillation
doit
se
composer
de
tuyaux,
raccords,
ciments
et
appréts
conformes
au
ULC
$636.
La
tuyauterie
de
ventilation
des
gaz,
ses
accessoires,
le
terminal
concentrique
mural
ainsi
que
l’ensemble
du
drain
de
condensation
extérieur
fourni
par
le
fabricant
de cette
fournaise
ont
été
certifiés
ULCS
636
pour
l’application
des
composantes
Royal
Pipe,
IPEX
PVC
qui
sont
certifiées
4
ce
standard.
Au
Canada,
l’apprét
et le
ciment
doivent
étre
du
méme
fabricant
que
le
systeme
d’évacuation.
L’apprét
GVS-65
(Purple)
et le
ciment-solvant
GVS-65
doivent
étre
utilisé
avec
les
Royal
Pipe.
Systeme
IPEX
636,
apprét
PVC/CPVC,
Purple
pour
évacuation
des
gaz
de
combustion
et
systéme
IPEX
636(1)t,
ciment
PVC
pour
évacuation
des
gaz
de
combustion,
coté
classe
IIA,
65
deg
C.
doivent
étre
utilisés
avec
le
systéme
d’évacuation
IPEX
636
Ne
pas
combiner
|
’apprét
et le
ciment
d’un
manufacturier
avec
un
systeme
d’évacuation
d’un
manutfacturier
différent.
Bien
suivre
les
indications
du
manufacturier
lors
de
l'utilisation
de
Papprét
et
du
ciment
et
ne
pas
utiliser
ceux-ci
si
la
date
d’
expiration
est
atteinte.
L’opération
sécuritaire,
tel
que
définit
par
ULC
S636,
du
systéme
de
ventilation
est
basé
sur
les
instructions
d’installation
suivantes,
ainsi
que
lusage
approprié
de
l’apprét
et
ciment.
Tout
arrét
feu
et
solin
de
toit
utilisés
avec
ce
systeme
doivent
étre
des
matériaux
listés
UL.
L’acceptation
du
standard
Canadien
CAN/CSA
B149
est
directement
relié
4
l’installation
conforme
aux instructions
ci-
haut
mentionnées.
Le
standard
Canadien
recommande
|’
inspection
par
un
personel
qualifié
et
ce,
une
fois
par
année.
Les
autoritées
ayant
juridiction
(inspecteurs
de gas,
inspecteurs
en
batiments,
département
des
incendies,
etc)
devraient
étre
consultées
avant
l’installation
afin
de
déterminer
si
un
permis
est
requis.
59SC2A

Other manuals for Carrier 59SC2A

Related product manuals