4 - PHYSICAL AND ELECTRICAL DATA
4.1 - Physical data
30XW-V/30XWHV 580 630 810 880 1150 1280 1470 1570 1710
Sound levels - standard unit
Sound power level
(1)
dB(A) 105 105 105 105 106 106 106 106 106
Sound pressure level at 1 m
(2)
dB(A) 87 87 87 87 87 87 87 87 87
Sound levels - standard unit + option 257
(3)
Sound power level
(1)
dB(A) 102 102 102 102 103 103 103 103 103
Sound pressure level at 1 m
(2)
dB(A) 84 84 84 84 84 84 84 84 84
Dimensions - standard unit
Length mm 3059 3059 3290 3290 4730 4730 4730 4730 4730
Width mm 1087 1087 1237 1237 1164 1164 1255 1255 1255
Height mm 1743 1743 1950 1950 1997 1997 2051 2051 2051
Operating weight
(4)
kg 3152 3190 4157 4161 7322 7398 7574 7770 7808
Compressors Semi-hermetic 06T screw compressors, 60 r/s
Circuit A - 1 1 1 1 1 1 1 1 1
Circuit B - - - - - 1 1 1 1 1
Oil - standard unit
Circuit A l 32 32 36 36 32 32 36 36 36
Circuit B l - - - - 32 32 32 36 36
Refrigerant - standard unit R-134a, GWP=1430 following ARI4
Circuit A
kg 130 130 180 175 120 120 115 115 110
teqCO
2
186 186 257 250 172 172 164 164 157
Circuit B
kg - - - - 120 120 120 115 110
teqCO
2
- - - - 172 172 172 164 157
Capacity control SmartVu
TM
, inverter-driven compressor, electronic expansion valve (EXV)
Minimum capcity % 20 20 20 20 10 10 10 10 10
Evaporator Multi-pipe ooded type
Water volume l 106 106 154 154 297 297 297 297 297
Water connections (Victaulic) in 6 6 8 8 8 8 8 8 8
Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000
Condenser Multi-pipe ooded type
Water volume l 112 112 165 165 340 340 340 340 340
Water connections (Victaulic) in 6 6 8 8 8 8 8 8 8
Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000
(1) In dB ref=10
-12
W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in
accordance with ISO 9614-1 and certied by Eurovent.3dB(A)). Measured in accordance with ISO 9614-1 and certied by Eurovent.
(2) in dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information,
calculated from the sound power level Lw(A).
(3) Option 257 = Low noise level
(4) Weight shown is guideline only. To nd out the unit refrigerant charge, please refer to the unit nameplate
12