Options No. Description Advantages
Use for 30XW-V
range
Dual relief valves on 3-way
valve
194
Three-way valve upstream of dual relief valves
on the evaporator and the oil separator
Valve replacement and inspection
facilitated without refrigerant loss.
Comforms to European standard EN378/
BGVD4
580-1710
Compliance with Swiss
regulations
197
Additional tests on the water heat exchangers.
Additional supply of PED documents,
supplementary certicates and test certicates.
Conformance with Swiss regulations 580-1710
Compliance with Russian
regulations
199 EAC certication Conformance with Russian regulations 580-1710
Compliance with Australian
regulations
200 Unit approved to Australian code Conformance with Australian regulations 580-1710
Low noise level
257 Evaporator piping sound insulation 3 dB(A) quiter than standard unit 580-1710
Welded evaporator water
connection kit
266 Victaulic piping connections with welded joints. Easy installation 580-1710
Welded condenser water
connection kit
267 Victaulic piping connections with welded joints. Easy installation 580-1710
Flanged evaporator water
connection kit
268 Victaulic piping connections with anged joints. Easy installation 580-1710
Flanged condenser water
connection kit
269 Victaulic piping connections with anged joints. Easy installation 580-1710
Thermal compressor
insulation
271
The compressor is covered with a thermal
insulation layer
Prevents air humidity to condensate on the
compressor surface
580-1710
EMC classication C2, as per 
EN 61800-3
282 Additional RFI lters on the unit power line
Reduces electromagnetic interferences.
Increase the variable frequency drive
(VFD) immunity level according to rst 
environment (so called, residential
environment) requirements and allow its
compliancy with emissions level required in
category C2
580-1710
Compliance with UAE
regulation
318
Additional label on the unit with rated power
input, rated current and EER following AHRI
550/590
Compliance with ESMA standard UAE.S
5010-5:2019.
580-1710
Compliance with Morocco
regulation
327
Specics documents according Morroco 
regulation
Conformance with Morocco regulations 580-1710