Troubleshooting
   
 
 
 
 
Carrier Connect™  
Wi-Fi Thermostat  Carrier Proprietary and Confidential  CARRIER CORPORATION ©2017  
Installation Guide  39  All rights reserved 
 
Fault definitions 
The following Fault messages are displayed and logged in the banner during the fault condition and then sent to 
the Cloud server. 
 
Temperature reading > 122°F 
•  Temperature reading = 0  
•  Reading not available 
Remote temperature > 122°F  
NOTE Displayed only if REMOTE SENSOR
 is set to 
INDOOR or AVERAGE. 
Remote temperature = 0  
NOTE Displayed only if REMOTE SENSOR is set to INDOOR or AVERAGE. 
Humidity sensor temperature > 122°F 
NOTE Displayed only if using humidity temperature as a backup source during a 
fault condition with the primary temperature sensor. 
Humidity sensor temperature = 0 
NOTE  Displayed only if using humidity temperature as a backup source during 
a fault condition with the primary temperature sensor. 
Indoor temperature is > 99.0°F 
Indoor temperature is < 40.0°F 
Any of the following: 
•  Humidity sensor timed out 
•  Humidity reading is > 99% 
•  Humidity reading is 0 
Humidity reading is > 90% 
Humidity reading is < 10% 
Valid packet has not been received from back PCB within last 15 seconds 
Not connected to Ayla server 
Router signal strength is 0 = no bars = not connected 
Communications error occurred with Wi-Fi module (resets after valid message 
received) 
Contact closure on remote sensor input, as determined by Economizer