62-61753-21   
 
1.4  SPECIFIC R-452A REFRIGERANT WARNING 
AND CAUTION 
 
R-452A is an  A1 non-flammable  refrigerant 
blend;  however  certain  of  its  constituents 
are considered A2L midly flammable. 
For this raison, it is imperative that the sys-
tem of a vector unit utilizing R-452A refrig-
erant  be  reclaim  to  a  sufficient  vaccum  to 
ensure  all  residual  refrigerant  is  removed 
from the system 
Follow  the  R-452A  refrigerant  reclaim  /  re-
covery  procedure  before  performing  any 
“Hot  work”  including  but  not  limited  to 
brazing or welding on a unit that has been 
charged with R-452A, to prevent flare up of 
residual A2L refrigerant constituents 
Refrigerant  must  be  reclaimed  until  equip-
ment  gauge  indicates  20  inHG  (-0.6bar)  of 
vacuum. 
Refer  to  Section  8.5.2Removing  The  R-
452A Refrigerant Charge  
Refer  to  the  Service  Bulletin  SB06-16  for 
additional information 
 
 
As  distinct  of  R404A  refrigerant,  R-452A 
has slidding properties more important and 
not  negligeable  between  vapour  state  and 
liquid state. 
For  a  given  temperature,  the  liquid  state 
pressure  value  and  the  vapour  state  pres-
sure  value,  of  the  R-452A  refrigerant  are 
differents. 
Refer  to  section  10  for  Temperature  pres-
sure chart