3.12  VIEW INACTIVE ALARMS 
COOL DEFROST ALARM START-STOP
ERUTAREPMETXOBTNIOPTES
ALARM LIST
SELECT
MANUAL
DEFROST
SUOUNITNOCTAEH
NO INACTIVE ALARMS
START--STOP/
CONTINU OUS
1. Press ALARM LIST key and the UP ARROW key and hold both for 6 seconds. If there
are no inactive alarms, “NO INACTIVE ALARMS” will be displayed for 5 seconds.
2. If there are inactive alarms, the alarm number will be displayed with the letter “I” in front and the
alarm message following.
3. Press the ALARM LIST or UP or DOWN key to scroll through the list of alarms.
4. When the end of the alarm list is reached, “LIST END, = TO CLEAR ALARMS” is displayed for 5
seconds.
5. To clear the active and inactive alarm list, press the “=” key while “LIST END, = TO CLEAR
ALARMS” is being displayed. “ALL ALARMS CLEARED” will be displayed.
+34. 5° F
--20.0
 
 
The  microprocessor  can  hold  up  to  16  alarms  in  the 
Active and Inactive Alarm Lists combined. The list can 
be  read  via  the  MessageCenter  or  using  the 
ReeferManager  PC  Program.  There  are  2  sections  in 
the  Alarm  List,  an  Active  Alarm  Section  and  Inactive 
Alarm  Section.  Ala²rms  in  these  sections  are  in  the 
order  in  which  the  alarms  activate  and  inactivate,  re-
spectively. On startup, all alarms are marked as inac-
tive.  If  an  alarm  then  becomes  active,  the  alarm  is 
moved from the Inactive Alarm List to the Active Alarm 
List. 
As additional alarms occur, they will be placed first  in 
the Active Alarm List. An alarm can not be active and 
inactive  at  the  same  time.  Each  alarm  can  only  be 
present  in  either  the  Active  or  Inactive  Alarm  List  at 
any given time. As conditions changed, alarms may be 
moved from the Active Alarm List to the Inactive alarm 
list and back.  
Alarms  are  also  recorded  in the Data  Recorder. They 
are  recorded  at  the  time  they  occur  (become  active), 
and the time they become inactive. 
For  a  complete  list  of  Alarms  and  troubleshooting  in-
formation refer to Section 7. 
TIP 
When  alarms  are  cleared  from  the  Inactive 
Alarm List, both active and inactive alarm lists 
are cleared. 
If  there  is  a  safety  shutdown,  "UNIT  SHUTDOWN  - 
SEE  ALARM  LIST"  will  be  displayed.  Refer  to  Sec-
tion 7 for complete list of Alarms and their descriptions. 
NOTE 
The  Inactive  Alarm  List  is  also  called  the 
Technician’s  List.  Only  qualified  refrigeration 
technicians should access the inactive list. It is 
not  intended  for  the  use  of  drivers  or  opera-
tors.