62-61753-21   
2.12  ELECTRICAL DATA 
System current limit - high speed: 16 amps 
System current limit - low speed: 14.5 amps 
0.83hp (610 watts) @ 65 Hz 
310 to 660 VAC; 45 to 65 Hz 
Factory lubricated, additional grease not required 
Clockwise when viewed from shaft end 
Resistance (cold) per rod 
U-type heater 97.6 ohms ±5 
One U-type heater & four straight heaters 
Resistance (cold) per rod 
U-type heater 187 ohms ±5 
Resistance (cold) per rod 
Straight heaters 93.5 ohms ±5 
Resistance (cold) per rod 
U-type heater 97.6 ohms ±5 
0.66 hp (485 watts) @ 65hz 
310 to 660 VAC 45 to 65 Hz 
Factory lubricated, additional grease not required 
Clockwise when viewed from inlet 
0.58 ohms (phase to neutral) 
16 KVA @ 0.82 p.f @ 1850 rpm 
12 volt nominal - 90 amp hour capacity 
Cold cranking amps = 425 DIN, 500 IEC, 725 BCI 
Standby Power 
Requirements