62-11039 5-6
CONFIGURATION
SELECTIONS DESCRIPTION
DISPLAYTOTALSWITCHONHR
NO / YES YES = This hourmeter will be displayed during the
startup messaging sequence and will be in hour-
meter menu.
NO = This hourmeter will not be displayed during
the startup messaging sequence and will be shown
with the “other meters and counters”.
DIESEL RESET VALUE
(Refer to Section 2.9 for oil change
intervals)
0
50 TO 30,000 HRS
in 50 hr increments
0 = The Engine Maintenance Hour Meter is turned
off.
50 – 30,000 hrs = The value selected here will be
the number of hours between engine service inter-
vals.
STANDBY RESET VALUE
0
50 TO 30,000 HRS
in 50 hr increments
0 = The Standby Run Time Maintenance Hour Me-
ter is turned off.
50 – 30,000 hrs = The value selected here will be
the number of hours between standby run time ser-
vice intervals.
SWITCH ON RESET VALUE
0
50 TO 30,000 HRS
in 50 hr increments
0 = The Switch--On Maintenance Hour Meter is
turned off.
50 – 30,000 hrs = The value selected here will be
the number of hours between Switch--On service
intervals.
PM (1--5) OFF
ENGINE HOURS
SWITCH ON
HOURS
STANDBY HOURS
START CYCLES
HIGH SPEED
HOURS
OFF = The PM 1--5 Maintenance Hour Meter(s) is
turned off.
ENGINE HOURS = PM Meter will count engine
hours until the next service interval.
SWITCH ON HOURS = PM Meter will count Switch
On Hours until the next service interval.
STANDBY HOURS = PM Meter will count Run
Time Hours until the next service interval.
START CYCLES = PM Meter will count how many
times the engine has started until the next service
interval.
HIGH SPEED HOURS = PM Meter will count how
many hours the unit operated in high speed until the
next service interval.