8-1262-11039
1. Screws
2. Cover plate
3. Blower housing
4. Evaporator fan
5. Spacer
6. Screw driver
7. Screws
7.
3.
4.
5.
6.
1.
2.
Figure 8 --10 Evaporator fan bolts
8.7.4 Condenser Fan And Motor Assemblies
The condenser fans pull air through the condenser coil
and discharges over the engine. To replace motor
assembly:
a. Open the front door
b. Disconnect wiring. Loosen securing bolts.
c. Remove motor assembly and replace the motor.
d. Install the condenser fan assembly in reverse order of
removal.
8.8 BATTERY CHARGER
8.8.1 Description
The battery charger is powered by the generator and
charges the 12 Vdc battery.
Figure 8 --11. Battery Charger
8.8.2 Checking Battery Charger
NOTE
The battery must be in good condition before
doing the following test.
1. Run the unit with the battery charger connected as
usual.
NOTE
If there is no load connected at the Vdc output,
the battery charger will not deliver voltage.
2. Put an ammeter on the +12 Vdc output of the battery
charger. If current are between 3 and 21 Amps the
battery charger is functioning correctly.
3. If Amps = 0 check the battery charger input AC volt-
age. It must be between 350 and 670 Volts.
4. If there is no AC voltage, stop the unit and, if re-
quired, disconnect the standby plug. Check the high
voltage 3--way connector and the 12 Vdc 2--way
connections.
5. If connections are good, replace battery charger.