9-7
62-11039
INDICATION/
TROUBLE
POSSIBLE CAUSES
REFERENCE
SECTION
REFRIGERATION (Continued)
9.4.5 Unit Will Not Terminate Heating
Controller improperly set Reset
Controller malfunction 9.4.9
Heater termination thermostat remains closed along with
the heat relay
Repair
9.4.6 Defrost Cycle Malfunction
Defrost air switch (DAS) out of calibration 8.25
A DTT is above 40_F(4.4_C) Cool Box Down
Will not initiate defrost
Defrost air switch (DAS) defective 8.24 & 8.25
au
oma
ca
y
Loose terminal connections Tighten
Air sensing tubes defective or disconnected Check
Microprocessor defective Replace
Loose terminal connections Tighten
not
n
t
ate
e
rost manua
y
DTT2 is above 40_F(4.4_C) Cool Box Down
Unit has been running less than 15 seconds Try again
Heater contactor or coil defective Replace
n
t
ates
ut
oes not
e
rost
Heater(s) burned out 8.7
Defrost air switch (DAS) out of adjustment 8.24 & 8.25
requent
e
rost
Wet load Normal