24
CAL 1 (CAL 1 automatically starts.)
Function: Setting Maximum Value
Range of set value: 1 ~ 99,999
Used key Display Descriptions
C= 10000
Max. value = 10000kg
:Save and next
Menu navigation
~ : Set value
change
:End
C= 10
Max. value = 10kg
Note 1. It means the maximum weight value to be weighed by the scale.
CAL 2
Function: Minimum division and decimal position setting
Range of set value: 0.001 ~ 9999
Used key Display Descriptions
d= 0.001
Minimum division 0.001 kg
d= 0.01
Minimum division 0.01 kg
d= 0.1
Minimum division 0.1 kg
d= 1
Minimum division 1 kg
:Save and next
Menu navigation
~ : Set value
change
:Set decimal point
and end
d= 10
Minimum division 10 kg
Note 1. To end CAL2, press key when a decimal point is set.
Note 2. The minimum division means the value of a division.
Note 3. Set the external resolution within 1/30,000 as the value by dividing the maximum weight by the minimum
division.
If the external resolution is 1/30,000 or more, Err 21 is shown.
Note 4. The position of a decimal point is decided by the position of a decimal point for the minimum division set
in CAL2.
Note 5. If the minimum division is set to any value out of 1, 2 and 5 unit, "ERR DIV" is shown.