Alarm troubleshooting
User Guide
User Guide
5-11
20052 Power Out of Range PoE source is delivering up to class 3. Verify PoE device supports
class 5 and has sufficient
power to feed the LTE
Network extender device.
Verify Ethernet cabling.
If possible, change to a
different switch port and wall
patch panel socket.
20053 RX RACH Overload A mobile phone is saturating the (RACH)
channel.
Power cycle the device to
clear the issue.
If symptom persists, please
contact Verizon Wireless
Customer Service.
20054 RX PUCCH
Overload
A mobile phone is saturating the (PUCCH)
channel.
Power cycle the device to
clear the issue.
If symptom persists, please
contact Verizon Wireless
Customer Service.
20055 RX PUSCH
Overload
A mobile phone is saturating the (PUSCH)
channel.
Power cycle the device to
clear the issue.
If symptom persists, please
contact Verizon Wireless
Customer Service.
20056 GPS Antenna not
connected
There is an issue with the GPS connector/
Antenna.
Ensure open view of the sky.
Reboot/power cycle the unit.
If the issue persists, replace
the GPS Antenna.
Table 5-2. Alarm troubleshooting (continued)
Unique
Alarm ID
(Code)
Alarm Description Recommendation