7
ELECTRICAL CONNECTION
Monophase 20A Meter
220-240V~ 50Hz
Electrical outlet
2 prong receptacle
+ ground lead
CEI Standard 60083
Monophase line 220-240 V ~
Power cable
length 1.50 m
approximately
A fuse or differential cir-
cuit breaker
Electrical safety must be provided by a cor-
rect build-in. During build-in and maintenance
operations, the appliance must be unplugged
from the electrical grid; fuses must be cut off
or removed.
The electrical connections are made before
the appliance is installed in its housing.
Ensure that:
- the electrical installation has sufficient volt-
age,
-the electrical wires are in good condition
- the diameter of the wires complies with the
installation requirements.
Your oven must be connected with a power
cord (standardised) with three 1.5 mm
2
con-
ductors (1 ph +1 N + ground) that must be
connected to a monophase 220-240 V
~ net-
work via a CEI 60083 standardised recepta-
cle (1 ph +1 N + ground lead) or an all-pole
cut-off device, in compliance with installa-
tion regulations.
Warning
The safety wire (green-yellow) is con
nected to the appliance’s terminal and
must be connected to the ground lead of the
electrical set-up.
In the case of a hook-up with electrical outlet,
it must be accessible after installation.
The fuse in your set-up must be 16 amperes.
If the power cable is damaged, it must be re-
placed by a cable or a special kit available
from the manufacturer or its After-Sales Ser-
vice Department.
2 / INSTALLING YOUR APPLIANCE