30 | Instruction Manual
cable of cross sectional area 1.5 mm²
• The current rating of the fuse or circuit breaker protecting this appliance
should be marked on the socket outlet
• Assembly and electrical connection should be carried out by specialised
personnel
• When installing this product we recommend you seek the help of
another individual
• Should the mains cable be damaged or need to be replaced, it should
only be done so by a qualified electrician or engineer
• The terminal block on the appliance is clearly marked with regards to
the positions of live, neutral and earth
Error Codes
If any error is detected, the programme is interrupted and the error code is
shown on the display:
E1 No cavity temperature sensor detected, do not use the
appliance.
E2 Short circuit or damage to the cavity temperature sensor, do
not use the appliance.
E3 Appliance overheated, do not use the appliance until it has
cooled down.
E6 Oven cavity temperature exceeding 320°C for functions other
than pyrolytic cleaning, or cavity temperature sensor
malfunction - do not use the appliance.