EasyManua.ls Logo

Center 261 - Page 8

Center 261
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TRMS AC/DC Low Current Clamp Meter
4
AC+DC A (True RMS)
Range Resolution
Accuracy
50~500Hz
40.00A 0.01A 2.5% + 5dgts
100.0A
0.1A
4.5% + 5dgts
200.0A 8.5% + 5dgts
DCV
Range Resolution Accuracy
6.000V 0.001V
1.0% + 2dgts
60.00V 0.01V
600.0V 0.1V
Input impedance: 1 M
ACV (True RMS)
Range Resolution
Accuracy
50~500Hz
6.000V 0.001V
1.2% ± 5dgts
60.00V 0.01V
600.0V 0.1V
Input impedance: 1 M
Zero correction: fractions smaller than approximately
0.010 V are calibrated to zero.
AC+DC V (True RMS)
Range Resolution
Accuracy
50~500Hz
6.000V 0.001V
1.5% ± 5dgts
60.00V 0.01V
600.0V 0.1V
Input impedance: 1 M