TRMS AC/DC Low Current Clamp Meter
3
3. ELECTRICAL SPECIFICATION
The accuracy specification is defined as ± ( percent of reading
+ digit ) at 23±5°C, 80 %RH.
DCmA
Range Resolution Accuracy
4000mA 1mA 2.0% + 5dgts
ACmA (True RMS)
Range Resolution
Accuracy
50~500Hz
4000mA 1mA 2.0% + 5dgts
AC+DC mA (True RMS)
Range Resolution
Accuracy
50~500Hz
4000mA 1mA 2.5% + 5dgts
DCA
Range Resolution Accuracy
40.00A 0.01A 2.0% + 5dgts
100.0A
0.1A
4.0% + 5dgts
200.0A 8.0% + 5dgts
ACA (True RMS)
Range Resolution
Accuracy
50~500Hz
40.00A 0.01A 2.0% + 5dgts
100.0A
0.1A
4.0% + 5dgts
200.0A 8.0% + 5dgts