2.1 Identify Garage Door type
Identify the garage door type and then select the preferred installation method
(Section.2.2) and assembly type (Section.2.3) that is best suited to the application.
2.2 Identify installation method
Method A -(Sectional door )
Use 3000mm long one piece or 3000mm three piece Drive Rail
The standard 3000mm Drive Rail will lift a door up to 2440mm high. (optional
Drive Rail extension kit is available for doors over 2440mm high)
XTrac is supported by the Drive Rail Hanger which is hung from the ceiling by
appropriate hanging material
Header Bracket may be mounted on front wall of garage or on ceiling adjacent to
the front wall
Method B -(Jamb type Tip-Up door )
Use 2000mm single piece rail or make up using two rail sections from the three
piece rail kit
XTrac is supported by the Drive Rail Hanger which is hung from the ceiling by
appropriate hanging material
Drive Rail must be angled as shown depicted in “Method B” so that the underside
of the Drive Unit is in line with underside of the garage door when the garage
doors are in the fully open (horizontal) position
Header Bracket may be mounted on front wall of garage or on the ceiling adjacent
to the front wall
Page 6
2. Assembly instructions
Method A
Installation to sectional door Installation to jamb-type tip up door
Towing bracket approx 1/3
of the way down from the
top panel. Bent towing arm
must be used and connected
to door with straight towing
arm connected to drive unit
Towing arm to top edge of
door. Bent towing arm must
be used and connected to
door with straight towing
arm connected to drive unit
Method B
FIGURE 1.