Forced learn
A Forced Learn may be initiated by holding down the Learn” Button
(Figure.19-D) for two seconds – LED Indicator will begin to quick flash
Cycle the XTrac through five complete uninterrupted strokes (commencing
from the close limit point) in order for it to complete the learning process
The LED Indicator will cease to quick flash once learning has been
completed
Important Note: During a Forced Learn the Safety Obstruction
Force values default to a maximum setting. Encounter a solid
obstruction during the course of the initial learning cycles may result
in garage door and / or property damage. It is recommended that the
learning cycles be carefully supervised during this time.
Automatic Re-Learn
A re-learn of Drive Force and Run Time parameters will be automatically
initiated immediately subsequent to either one of the following
occurrences;
a. Run Time deviation becoming excessive
b. Safety Reversing on three consecutive occasions
c. Safety Stopping on three consecutive occasions
During this period the LED Indicator will quick flash
4.2.2 Manual (M) Mode
Enabling
If Adaptive Mode is your desired selection, then refer to Section.4.2.1
To enable Manual Mode;
I. switch off power at power supply
II. remove the Courtesy Lamp and Control Box Covers to
expose the Control Board (Refer Sec.19 for removal and replacement
details)
III. select Dipswitch No.1 to the “OFF” position (Figure.17)
IV. replace the Control Box and Lamp Covers
V. switch power on at power supply
Entering Safety Obstruction Force Adjustment mode
Hinge open the Courtesy Lamp Cover to expose the adjustment controls.
(Figure.19)
Press and hold down the “Learn” Button (Figure.19-D) for two seconds -
LED Indicator will commence a paused double flash.
Safety Obstruction Force Adjustment can be carried out while LED
Indicator is “paused double flashing”
To close out Safety Obstruction Force Adjustment Mode momentarily
press “Learn” Button