Page 2
Failure to adequately lubricate the springs may result
in one or more of the following symptoms:
Counterbalance springs may become rusty over time
resulting in additional operating friction between the
coils which may cause the XTrac to malfunction
Seasonal temperature changes may cause the garage
door springs to expand and / or contract. The
resultant increase and / or decrease in operating
friction may cause the XTrac to malfunction. Properly
lubricating the springs will help to minimize changes
in operating friction due to the effects of seasonal
temperature change
Remove or render inoperative all existing locks and
ropes prior to installation of the XTrac
Repairs to the garage door must be carried out by
technically qualified persons. Attempting to repair the
garage door without suitable technical qualification may
result in severe personal injury, death and / or property
damage
Where possible, install the XTrac at least two meters or
more above the ground. Adjust the Engage / Disengage
Cord so that it hangs approximately 1.8 meters from the
ground
The Header Bracket carries ALL of the opening and
closing thrust of the XTrac and as such must be securely
fastened to a rigid, structural member of the garage wall
or ceiling. It is entirely up to the installer to determine
the fixing method and the structural suitability of the
fixing points
The ceiling structure must be adequate to support the
weight of the XTrac. It is entirely up to the installer to
determine the structural suitability of the fixing points
The Engage / Disengage Instruction Tag must remain
attached to the Engage / Disengage Cord.
Locate the Wall Switch;
within site of the garage door, and
at a minimum height of 1.5 meters above the ground
so that it remains out of the reach of small children,
and
away from all moving parts of the garage door
The Entrapment Warning Label must be secured in a
prominent position adjacent to the wall switch
The XTrac must be connected to a properly earthed
general purpose 220-240V AC power outlet which has
been installed by a qualified electrical contractor.
Do not connect the XTrac to the power outlet until this
manual instructs you to do so