63
GB
technical features
Technical data
Power supply BUS
Electrical absorption max. < 0.5 W
Operating temperature -10 ÷ 60°C
Storage temperature -20 - 70°C
Bus wire length and cross-sectional area
NOTE:
TO AVOID INTERFERENCE PROBLEMS, USE A SHIELDED CABLE OR
TWISTED PAIR CABLE.
max. 50 m - min. 0.5 mm²
Buffer memory 2 h
Conformity
LVD 2014/35/EU - EMC 2014/30/EU
Electromagnetic interference EN 60730-1
Electromagnetic emissions EN 60730-1
Conformity to standards EN 60730-1
Temperature sensor NTC 5 k 1%
Resolution degree: 0.1°C
134 mm 16 mm
96 mm
Sensys Product Fiche
Supplier name Chaffoteaux
Supplier identifi cation model Expert Control
Temperature control class V
Energy effi ciency contribution (%) for space heating +3%
Addition of an outdoor sensor:
Temperature control class VI
Energy effi ciency contribution (%) for space heating +4%
In a system with 3 zones with 2 room sensors:
Class of the temperature control VIII
Contribution to seasonal space heating energy effi ciency in % +5%