NVF5 Series User Manual  Chapter 6 Parameter Function Description 
6.2 Frequency Reference Setting 
There are threr kinds of frequency reference modes,Main frequency reference、Aux. 
frequency reference、Main and aux. frequency reference sum mode. 
6.2.1 Main Frequency Reference Selection 
Set parameter F0.02,select main frequency reference.There are 9 kinds of main 
frequency reference modes. 
Code  Name  Default 
Description 
F0.02 
Main Frequency 
Source Selection 
0 
6.2.2 Setting Main Frequency Reference in Keypad(Digital Given) 
Set main frequency reference in keypad(Digital Given),there are 4 kinds of modes to 
set main frequency reference using UP、DOWN to set  : 
 When parameter F0.13 ones place is 0(No memory when power off), that is to
say when the inverter stop or re-power on,the setting frequency value will recover
to the value of parameter F0.05 setting.
 When parameter F0.13 ones place is 1(Memory when power off), that is to say
when the inverter power failure and power on again,the setting frequency value is
the value of the last power failure.
 When parameter F0.13 tens place is 1(Stop frequency recover to initial value),Set
parameter F0.05-Digital Given Frequency using integral keypad,then using UP、
DOWN key on the keypad to adjust frequency reference,the update frequency
value will be cleared when inverter stops.
 When parameter F0.13 tens place is 0(Inverter stop but frequency reference
hold)F0.13,Set parameter F0.05-Digital Given Frequency using integral keypad,
then using UP、DOWN key on the keypad to adjust frequency reference, the
update frequency value will be reserved when inverter stops.
Code  Name  Default  Setting Range  Description 
F0.05  Digital Given  5.00Hz  F0.09  ~  F0.08  - 
F0.07 
Digital Given 
50.00Hz  F0.08  ~  600.00Hz  - 
- 42 -