19
System Statuses
System Armed
In this mode, all of the sensors are on alert; the hub’s built-in siren will sound when
a sensor is triggered. You and ALL other pre-authorized users will receive push
notications, SMS and phone calls (if phone numbers have been stored).
This mode is recommended to use when no one is at home, it can be easily set from
the remote control or App.
System in Home Mode (Partial Arm or Stay Mode)
Only Home Zone sensors will stop detecting under this mode, which enables you and
your family to move freely inside your home without accidentally triggering an alarm.
This mode is recommended when someone is at home, such as during the night, and
can be easily set from the remote control or App.
Note: The Door/window sensor in this kit has been set to Normal Zone by default
and the Motion Detector has been set to Home Zone, you can refer to page (25) and
change their zone mode on the “Accessory Settings” page of the App.
System Disarmed
All the sensors stop detecting except any sensors that you may have set to 24-Hour
Zone. 24-Hour Zone sensors will continuously monitor a particular area. For example,
an extra water sensor (Set to 24-Hour Zone by default) that has been paired with
Hub and installed near a washing machine would trigger alarm if water is detected,
regardless of system status.
System in SOS Mode
In this mode, the hub’s built-in siren sounds to alert. You and ALL other pre-
authorized users will receive notications.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chuango H4 PLUS and is the answer not in the manual?

Chuango H4 PLUS Specifications

Hub

Power IconPower
power supply voltageDC 12V
power supply current500mA
battery voltage3.7V
battery capacity2600mAh
Operating Environment IconOperating Environment
operating temperature range0°C ~ +55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
hub dimensions160 x 160 x 45mm
bracket dimensions80 x 80 x 10mm

Remote Control

Power IconPower
power supply voltageDC 3V
transmit current<7mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
dimensions58 x 31 x 9.5mm

Door/Window Sensor

Power IconPower
power supply voltageDC 1.5V
static current<35uA
alarm current<40mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
transmitter dimensions71 x 34 x 17.5mm
magnet dimensions51 x 12 x 13.5mm

PIR Motion Detector

Power IconPower
power supply voltageDC 3V
static current<18uA
alarm current<12mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
sensor dimensions108 x 52 x 36.8mm
bracket dimensions52 x 30 x 26.5mm