Getting to Know Your System
This is a dual network system that utilizes both WiFi and Cellular. When the WiFi is in
use, the Cellular network will be in standby status (make sure the Cellular function is
activated from “Settings“- ”My Hub“-”Cellular “). In the event of AC power loss or WiFi
disconnection, the Cellular network will be implemented until power or WiFi connection is
reestablished.
All sensors are wirelessly linked to the hub. In the event of alarm activation, for example,
when a sensor is triggered, a push notication will automatically be sent and an alarm call
will be made to all registered users.
The system can be controlled and monitored both on-site by using the remote control
supplied or remotely from anywhere in the world with our free dedicated mobile
application.
The system can be expanded to include up to 50 wireless sensors and 10 remote
controls.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chuango H4 PLUS and is the answer not in the manual?

Chuango H4 PLUS Specifications

Hub

Power IconPower
power supply voltageDC 12V
power supply current500mA
battery voltage3.7V
battery capacity2600mAh
Operating Environment IconOperating Environment
operating temperature range0°C ~ +55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
hub dimensions160 x 160 x 45mm
bracket dimensions80 x 80 x 10mm

Remote Control

Power IconPower
power supply voltageDC 3V
transmit current<7mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
dimensions58 x 31 x 9.5mm

Door/Window Sensor

Power IconPower
power supply voltageDC 1.5V
static current<35uA
alarm current<40mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
transmitter dimensions71 x 34 x 17.5mm
magnet dimensions51 x 12 x 13.5mm

PIR Motion Detector

Power IconPower
power supply voltageDC 3V
static current<18uA
alarm current<12mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
sensor dimensions108 x 52 x 36.8mm
bracket dimensions52 x 30 x 26.5mm