07
Remote Control
Arm Button
LED Indicator
Disarm Button
SOS Button
Home Arm Button
Description of Indicator Light
Buttons System Status
All sensors will be armed. This mode is used when the property is
unoccupied.
All sensors will be disarmed.
Note: When the system is set to ‘Disarm’, sensors in 24-Hour Zone (ood
sensors, smoke detectors, etc) will remain active.
Sensors which are set to the Home Zone will be disarmed. All other
sensors will be armed. This mode allows for movements within the
property without triggering the Home Zone sensor(s), such as motion.
This will trigger an ‘emergency’ alert notication to registered users
regardless of the hub mode.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chuango H4 PLUS and is the answer not in the manual?

Chuango H4 PLUS Specifications

Hub

Power IconPower
power supply voltageDC 12V
power supply current500mA
battery voltage3.7V
battery capacity2600mAh
Operating Environment IconOperating Environment
operating temperature range0°C ~ +55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
hub dimensions160 x 160 x 45mm
bracket dimensions80 x 80 x 10mm

Remote Control

Power IconPower
power supply voltageDC 3V
transmit current<7mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
dimensions58 x 31 x 9.5mm

Door/Window Sensor

Power IconPower
power supply voltageDC 1.5V
static current<35uA
alarm current<40mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
transmitter dimensions71 x 34 x 17.5mm
magnet dimensions51 x 12 x 13.5mm

PIR Motion Detector

Power IconPower
power supply voltageDC 3V
static current<18uA
alarm current<12mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
sensor dimensions108 x 52 x 36.8mm
bracket dimensions52 x 30 x 26.5mm