01
Things to Note before Getting Started
WiFi Network Connection
- One critical factor affecting the performance of your hub is the relative position/
distance of your home WiFi router and the hub. Place your hub in an open area (DO
NOT place it directly on the oor); the closer the hub is to the router, the stronger the
WiFi signal is.
- A slow network speed will also affect the performance of your hub. It is
recommended that you have an upload speed of at least 2Mbps or faster.
- Please be sure to connect your hub to WiFi using the 2.4GHz band as this provides
longer range, and better reception through walls. The hub does not support the
5GHz option. Selecting the 5GHz band instead of the 2.4GHz band is the most
common mistake when setting up the hub for the rst time.
For more information about your network quality, we recommend www.speedtest.net
or the speedtest app by Ookla.
Your WiFi Network and Password
- Check for your WiFi network’s name and password and write them down for easy
reference. The WiFi network name is commonly referred to as the SSID. The password
or security ID is normally the next line or two down from the WiFi/SSID network name.
Unless you’ve changed your network’s name and password, you can usually nd them
printed on the side of your router box, for example:
- WiFi/SSID Network Name: XXXX
- WiFi/SSID Network Password/Security Key: XXXXX
System Requirements
-iOS 8.0 or above with iPhone 5 or above
-Android 5.0 or above

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chuango H4 PLUS and is the answer not in the manual?

Chuango H4 PLUS Specifications

Hub

Power IconPower
power supply voltageDC 12V
power supply current500mA
battery voltage3.7V
battery capacity2600mAh
Operating Environment IconOperating Environment
operating temperature range0°C ~ +55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
hub dimensions160 x 160 x 45mm
bracket dimensions80 x 80 x 10mm

Remote Control

Power IconPower
power supply voltageDC 3V
transmit current<7mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
dimensions58 x 31 x 9.5mm

Door/Window Sensor

Power IconPower
power supply voltageDC 1.5V
static current<35uA
alarm current<40mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
transmitter dimensions71 x 34 x 17.5mm
magnet dimensions51 x 12 x 13.5mm

PIR Motion Detector

Power IconPower
power supply voltageDC 3V
static current<18uA
alarm current<12mA
Operating Environment IconOperating Environment
operating temperature range0°C~+55°C
relative humidity<80% (Non-condensing)
Dimensions IconDimensions
sensor dimensions108 x 52 x 36.8mm
bracket dimensions52 x 30 x 26.5mm