12
2.18. Error message『Err1』:Inverter no output after start.
Does the console show
『UArt』after 10
seconds?
Refer to 2.13. error
message『UArt』
Press START to quick start.
Motor did not move then
show Err1?
Replace inverter to newest version
(refer to 1.3.) and update the
console firmware version to the
newest version.(great than V1.05)
Set incline to level 15 then set
to level 0.
Does the incline work abnormal
and stop then show Err1?
System operating normal but please
check the inverter shall be the new
version and console firmware version
great than V1.05, if not, replace or
update it.
The incline motor jammed or input power too low, the
input power shall over 90V(110V system)/200V(220V
system). After to eliminate incline motor jammed and
input power problem, please check the inverter shall be
the new version (refer to 1.3.) and console firmware
version great than V1.05, if not, replace or update it.