Cirrus Design Section 3A
SR22 Abnormal Procedures
P/N 13772-002 3A-3P/N 13772-002 3A-3
Introduction
This section provides procedures for handling abnormal system and/or
flight conditions which, if followed, will maintain an acceptable level of
airworthiness or reduce operational risk. The guidelines described in
this section are to be used when an abnormal condition exists and
should be considered and applied as necessary.
• Caution •
If a Warning annunciation is illuminated in combination with
any of the following Abnormal annunciations, the Warning
annunciation takes precedents and shall be performed first.
Abnormal Procedures Guidance
Although this section provides procedures for handling most abnormal
system and/or flight conditions that could arise in the aircraft, it is not a
substitute for thorough knowledge of the airplane and general aviation
techniques. A thorough study of the information in this handbook while
on the ground will help you prepare for time-critical situations in the air.
Sound judgement as well as thorough knowledge of the aircraft, its
characteristics, and the flight manual procedures are essential in the
handling of any abnormal system and/or flight condition. In addition to
the outlined items in the Abnormal Procedures, the following steps are
considered part of all abnormal situations:
Maintain Aircraft Control
•Analyze the Situation
Take Appropriate Action
Circuit Breakers
Many procedures involve manipulating circuit breakers. The following
criteria should be followed during “Circuit Breaker” steps:
Circuit breakers that are “SET” should be checked for normal
condition. If the circuit breaker is not “Set”, it may be reset only
once. If the circuit breaker opens again, do not reset.
Circuit breakers that “PULL” should only be pulled and not reset.
Circuit breakers that “CYCLE” should be pulled, delayed for
several seconds, and reset only once. Allow sufficient cooling
time for circuit breakers that are reset through a “CYCLE”
procedure.
Reissue A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cirrus DESIGN SR22 and is the answer not in the manual?

Cirrus DESIGN SR22 Specifications

General IconGeneral
BrandCirrus
ModelDESIGN SR22
CategoryAircrafts
LanguageEnglish

Related product manuals