3-19
Hardware Installation Guide for Cisco 4000 Series Integrated Services Routers
OL-32185-02
Chapter 3 Install and Connect Cisco 4000 Series ISRs
Chassis Grounding
After the router is installed, you must connect the chassis to a reliable earth ground. For the chassis
ground connection procedures, see the “Chassis Grounding” section on page 3-19.
Chassis Grounding
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment
in the absence of a suitably installed ground conductor. Contact the appropriate electrical
inspection authority or an electrician if you are uncertain that suitable grounding is available.
Statement 1024
Warning
During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not
directly touch the backplane with your hand or any metal tool, you could shock yourself.
Statement 94
You must connect the chassis to a reliable earth ground; the ground wire must be installed in accordance
with local electrical safety standards.
For grounding, use size 6 AWG (13 mm
2
) copper wire and the ground lug provided in the accessory
kit.
Note This equipment is suitable for installation in Network Telecommunications Facilities and
locations where the NEC applies. The equipment is suitable for installation as part of the
Common Bonding Network (CBN).
For NEC-compliant grounding, use size 14 AWG (2 mm
2
) or larger copper wire and an appropriate
user-supplied ring terminal with an inner diameter of 1/4 in. (5–7 mm).
For EN/IEC 60950-compliant grounding, use size 18 AWG (1 mm
2
) or larger copper wire and an
appropriate user-supplied ring terminal.
To install the ground connection for your router, perform the following steps:
Step 1 Strip one end of the ground wire to the length required for the ground lug or terminal.
For the ground lug—approximately 0.75 inch (20 mm)
For user-provided ring terminal—as required
Step 2 Crimp the ground wire to the ground lug or ring terminal, using a crimp tool of the appropriate size.
Step 3 Attach the ground lug or ring terminal to the chassis as shown in Figure 3-13. For a ground lug, use the
two screws with captive locking washers provided. For a ring terminal, use one of the screws provided.
Tighten the screws to a torque of 8 to 10 in-lb (0.9 to 1.1 N-m).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 4221 ISR and is the answer not in the manual?

Cisco 4221 ISR Specifications

General IconGeneral
Form FactorRack-mountable
WAN Ports2
LAN Ports2
RAM4 GB
Flash Memory4 GB
Product TypeRouter
Total Number of Ports4
Number of Network (RJ-45) Ports4
Number of Total Expansion Slots3
Expansion Slot TypeNIM, ISC
Number of NIM Slots2
Number of ISC Slots1
ManageableYes
Power SupplyInternal
Redundant Power SupplyNo
Authentication MethodRADIUS, TACACS+
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab
Operating Temperature32°F to 104°F (0°C to 40°C)
Height1.75 in
Encryption AlgorithmAES, 3DES
Dimensions (W x D x H)1.75 x 13.5 x 1.73 inches
Operating Humidity5 to 95% (noncondensing)