7-38
Cisco ASR 1000 Series Aggregation Services Routers Software Configuration Guide
OL-16506-10
Chapter 7 Configuring Call Home
Alert Group Trigger Events and Commands
— — %ASR1000_PEM-3-FANFAIL 3 The fan in slot (slot/subslot
number) is encountering a failure
condition.
— — %ASR1000_PEM-6-FANOK 6 The fan in slot (slot/subslot
number) is functioning properly.
— — %ASR1000_PEM-3-PEMFAIL 3 The PEM in slot (slot number) is
switched off or encountering a
failure condition.
— — %ASR1000_PEM-6-PEMOK 6 The PEM in slot (slot number) is
functioning properly.
— — %ENVIRONMENTAL-1-ALERT 1 Any sensor in fp/cc/rp has exceeded
a certain threshold and resulted in
this environmental alert.
— ENVM %ENVIRONMENTAL-1-SENSORFAIL 1 Any sensor in fp/cc/rp has failed
and resulted in this environmental
alert.
— — %ENVIRONMENTAL-1-SENSOROK 1 Any sensor in fp/cc/rp has
recovered and resulted in this
environmental alert.
Inventory — — — Inventory status should be provided
whenever a unit is cold-booted, or
when FRUs are inserted or
removed. This is considered a
noncritical event, and the
information is used for status and
entitlement. (Sent to TAC.)
CLI commands executed:
show platform
show inventory oid
show version
show diag all eeprom detail
— SPA
HARDWARE_
REMOVAL
%ASR1000_OIR-6-REMSPA 6 SPA removed from subslot
(slot/subslot number) and the
interfaces are disabled.
— SPA
HARDWARE_I
NSERTION
%ASR1000_OIR-6-INSSPA 6 SPA inserted in subslot (slot/subslot
number).
— CC/FP/RP
HARDWARE_
REMOVAL
%ASR1000_OIR-6-REMCARD 6 Card (cc/rp/fp) removed from slot
(slot number).
— CC/FP/RP
HARDWARE_I
NSERTION
%ASR1000_OIR-6-INSCARD 6 Card (cc/rp/fp) inserted in slot (slot
number).
Table 7-3 Call Home Alert Groups, Events, and Actions (continued)
Alert Group
Call Home
Trigger Event Syslog Event Severity
Description and CLI Commands
Executed