Removing an AC Power Supply
To remove a Cisco ASR 1002 Router AC power supply that is not operating normally (and then replace the AC power supply
within five minutes), follow this procedure:
Step 1 Slip on the ESD-preventive wrist strap that was included in the accessory kit.
Step 2 Turn the switch to the off (O) position and unplug the AC power cord.
Step 3 Unscrew all of the power supply captive screws.
Step 4 Grasping the power supply handles, pull the power supply from the chassis. When you remove the AC power supply,
you will see the following type of messages in the log report:
#show log
Syslog logging: enabled (0 messages dropped, 6 messages rate-limited, 0 flushes, 0 overruns, xml
disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 81 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 78 message lines logged
Log Buffer (10000000 bytes):
*Jan 10 06:08:14.713: %CMRP-3-PEM_REMOVE_SHUT: R0/0: cmand: The system will shut down in 5 minutes
*Jan 10 06:08:14.718: %ASR1000_PEM-6-REMPEM_FM: PEM/FM slot P1 removed
*Jan 10 06:08:28.966: %ASR1000_PEM-6-INSPEM_FM: PEM/FM slot P1 inserted
The second is after enabling console logging. Output is at the console (and in the log).
2ru_perf2#conf Configuring from terminal, memory, or network [terminal]?
Enter configuration commands, one per line. End with CNTL/Z.
2ru_perf2(config)#log con
% Ambiguous command: "log con"
2ru_perf2(config)#logg con
2ru_perf2(config)#^Z
2ru_perf2#
*Jan 10 06:08:54.643: %SYS-5-CONFIG_I: Configured from console by console
2ru_perf2#
2ru_perf2# *Jan 10 06:09:05.023: %CMRP-3-PEM_REMOVE_SHUT: R0/0: cmand: The system will shut down in 5
minutes
*Jan 10 06:09:05.026: %ASR1000_PEM-6-REMPEM_FM: PEM/FM slot P0 removed
*Jan 10 06:09:10.500: %ASR1000_PEM-6-INSPEM_FM: PEM/FM slot P0 inserted
2ru_perf2#
Step 5 Replace the AC power supply within five minutes or the system will shutdown
You have removed an AC power supply from the Cisco ASR 1002 Router and now must replace the AC power supply within
five minutes. For replacing the AC power supply into the Cisco ASR 1002 Router, see Connecting AC Power to the Cisco ASR
1002 Router, page 17.