7-9
Cisco Nexus 1000V Troubleshooting Guide, Release 5.2(1)SV3(1.1)
OL-31593-01
Chapter 7 VSM and VEM Modules
Problems with the VSM
Step 1 On the VSM, verify that the control and packet VLANs are present.
switch# show running-config vlan 260-261
version 4.0(4)SV1(3)
vlan 260
name cp_control
vlan 261
name cp_packet
switch#
. . .
Step 2 Find the AIPC MAC address of the VSM on the VSM.
switch(config-svs-domain)# show svs neighbors
Active Domain ID: 27
AIPC Interface MAC: 0050-56bc-74f1 <-------------
inband/outband Interface MAC: 0050-56bc-62bd
Src MAC Type Domain-id Node-id Last learnt (Sec. ago)
------------------------------------------------------------------------
0050-56bc-6a3d VSM 27 0201 771332.97
0002-3d40-1b02 VEM 27 0302 51.60
0002-3d40-1b03 VEM 27 0402 51.60
Step 3 Find the DPA MAC address of the VEM on the ESX host.
switch# vemcmd show card
Card UUID type 2: 24266920-d498-11e0-0000-00000000000f
Card name:
Switch name: Nexus1000v
Switch alias: DvsPortset-0
Switch uuid: ee 63 3c 50 04 b1 6d d6-58 61 ff ba 56 05 14 fd
Card domain: 27
Card slot: 3
VEM Tunnel Mode: L2 Mode
VEM Control (AIPC) MAC: 00:02:3d:10:1b:02
VEM Packet (inband/outband) MAC: 00:02:3d:20:1b:02
VEM Control Agent (DPA) MAC: 00:02:3d:40:1b:02 <-------------
VEM SPAN MAC: 00:02:3d:30:1b:02
Primary VSM MAC : 00:50:56:bc:74:f1
Primary VSM PKT MAC : 00:50:56:bc:62:bd
Primary VSM MGMT MAC : 00:50:56:bc:0b:d5
Standby VSM CTRL MAC : 00:50:56:bc:6a:3d
Management IPv4 address: 14.17.168.1
Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
Primary L3 Control IPv4 address: 0.0.0.0
Secondary VSM MAC : 00:00:00:00:00:00
Secondary L3 Control IPv4 address: 0.0.0.0
Upgrade : Default
Max physical ports: 32
Max virtual ports: 216
Card control VLAN: 168
Card packet VLAN: 168
Control type multicast: No
Card Headless Mode : No
Processors: 16
Processor Cores: 8
Processor Sockets: 2
Kernel Memory: 25102148
Port link-up delay: 5s
Global UUFB: DISABLED

Table of Contents