DescriptionStatusLEDComponent
The operator has activated this LED to identify this switch in the
chassis.
Blinking (blue)BCNCPU Card
(N9K-C9400-SUP-A)
This module is not being identified.Off
All diagnostics pass. The module is operational.
Solid on (green)STS
The module is booting up.
The module is not receiving power.
Blinking (amber)
Temperature exceeds the minor alarm threshold.On (amber)
Temperature exceeds the major alarm threshold.Solid on (red)
Fans and power supply modules are operational
Solid on (green)ENV
At least one fan or power supply module is not operating.Solid on (amber)
Synchronization of the frequency to external interface. The external
interface could be (GPS, Recovered RX clk).
Solid on (green)SYNCE
Freerun/holdover- Time core is in freerun or holdover mode.Solid on (amber)
Time core clock synchronization is disabled.Off
Synchronization of the time and phase to external interface. The
external interface could be (GPS, FP)
Solid on (green)TIMING
Freerun/holdover- Time core is in freerun or holdover mode.Solid on (amber)
Time core clock synchronization is disabled.Off
GPS interface provisioned and ports are turned on. ToD, 1PPS,
10MHz are all valid.
Solid (green)GPS
Either the interface is not provisioned, or the ports are not turned
on. ToD, 1PPS, 10MHz are not valid.
Off
The MGMT port is link up.
Solid (green)MGMT link
The MGMT port is not link up.Off
The MGMT port is transmitting or receiving.
Blinking (green)MGMT activity
The MGMT port is not transmitting or receiving.Off
LEM LEDs
This table provides information about Line Expansion Module (LEM) LEDs for Cisco Nexus 9400 Series
switches.
Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide
58
LEDs
LEM LEDs