Administration: Discovery
Discover - LLDP
Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x 120
8
PD Requested Power Value—Amount of power allocated by the PSE to the PD.
PSE Allocated Power Value—Amount of power allocated to the sourcing equipment
(PSE).
802.3 Energy Efficient Ethernet (EEE) (If device supports EEE)
Local Tx—Indicates the time (in micro seconds) that the transmitting link partner waits
before it starts transmitting data after leaving Low Power Idle (LPI mode).
Local Rx—Indicates the time (in micro seconds) that the receiving link partner requests
that the transmitting link partner waits before transmission of data following Low
Power Idle (LPI mode).
Remote Tx Echo—Indicates the local link partners reflection of the remote link
partners Tx value.
Remote Rx Echo—Indicates the local link partners reflection of the remote link
partners Rx value.
4-Wire Power via MDI
4-Pair PoE Supported—Indicates system and port support enabling the 4-pair wire
(true only for specific ports that have this HW ability).
Spare Pair Detection/Classification Required—Indicates that the 4-pair wire is
needed.
PD Spare Pair Desired State—Indicates a pod device requesting to enable the 4-pair
ability.
PD Spare Pair Operational State—Indicates whether the 4-pair ability is enabled or
disabled.
MED Details
Capabilities Supported—MED capabilities supported on the port.
Current Capabilities—MED capabilities enabled on the port.
Device Class—LLDP-MED endpoint device class. The possible device classes are:
- Endpoint Class 1—Generic endpoint class, offering basic LLDP services.
- Endpoint Class 2—Media endpoint class, offering media streaming capabilities, as
well as all Class 1 features.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350-28 and is the answer not in the manual?

Cisco SG350-28 Specifications

General IconGeneral
ModelSG350-28
CategorySwitch
Switching Capacity56 Gbps
LayerLayer 3
Power SupplyInternal
Form FactorRack-mountable
Relative Humidity10% to 90% non-condensing
MAC Address Table Size16K entries
Power Dedicated to PoENot applicable
Dimensions (W x D x H)440 x 257 x 44 mm
Operating Temperature0°C to 45°C
Storage Temperature-20°C to 70°C
Power Consumption24W
Input Voltage100-240V AC, 50/60Hz
Jumbo Frame SupportSupported
Weight3.2 kg