Port Management
Error Recovery Settings
145 Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x
9
Error Recovery Settings
This page enables automatically reactivating a port that has been shutdown because of an error
condition after the Automatic Recovery Interval has passed.
To configure error recovery settings:
STEP 1 Click Port Management > Error Recovery Settings.
STEP 2 Enter the following fields:
Automatic Recovery Interval—Specify the time delay for automatic error recovery, if
enabled, after a port is shutdown.
Automatic ErrDisable Recovery
- Port Security—Select to enable automatic error recovery when the port has been
shut down for port security violations
- 802.1x Single Host Violation—Select to enable automatic error recovery when the
port has been shut down by 802.1x.
- ACL Deny—Select to enable automatic error recovery mechanism by an ACL
action.
- STP BPDU Guard—Select to enable automatic error recovery mechanism when
the port has been shut down by STP BPDU guard.
- STP Loopback Guard— Enable automatic recovery when the port has been shut
down by STP Loopback Guard.
- UDLD—Select to enable automatic error recovery mechanism for the UDLD
shutdown state.
- Loopback Detection—Select to enable error recovery mechanism for ports shut
down by loopback detection.
- Storm Control—Select to enable error recovery mechanism for ports shut down by
storm control.
- Link Flap Prevention—Select to minimize the disruption to your network.
Enabled, this command automatically disables ports that experience link-flap
events.
STEP 3 Click Apply to update the global setting.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350-28 and is the answer not in the manual?

Cisco SG350-28 Specifications

General IconGeneral
ModelSG350-28
CategorySwitch
Switching Capacity56 Gbps
LayerLayer 3
Power SupplyInternal
Form FactorRack-mountable
Relative Humidity10% to 90% non-condensing
MAC Address Table Size16K entries
Power Dedicated to PoENot applicable
Dimensions (W x D x H)440 x 257 x 44 mm
Operating Temperature0°C to 45°C
Storage Temperature-20°C to 70°C
Power Consumption24W
Input Voltage100-240V AC, 50/60Hz
Jumbo Frame SupportSupported
Weight3.2 kg