SNMP
Trap Settings
371 Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x
21
Read Write—Management access is read-write. Changes can be made to the device
configuration, but not to the community.
SNMP Admin—User has access to all device configuration options, as well as
permissions to modify the community. SNMP Admin is equivalent to Read Write
for all MIBs except for the SNMP MIBs. SNMP Admin is required for access to the
SNMP MIBs.
- View Name—Select an SNMP view (a collection of MIB subtrees to which access
is granted).
(Community Type) Advanced—Select this type for a selected community.
- Group Name—Select an SNMP group that determines the access rights.
STEP 4 Click Apply. The SNMP Community is defined, and the Running Configuration is updated.
Trap Settings
The Trap Settings page enables configuring whether SNMP notifications are sent from the
device, and for which cases. The recipients of the SNMP notifications can be configured in the
SNMPv1.2 Notification Recipients page, or the SNMPv3 Notification Recipients page.
To define trap settings:
STEP 1 Click SNMP > Trap Settings.
STEP 2 Select Enable for SNMP Notifications to specify that the device can send SNMP
notifications.
STEP 3 Select Enable for Authentication Notifications to enable SNMP authentication failure
notification.
STEP 4 Click Apply. The SNMP Trap settings are written to the Running Configuration file.
Notification Recipients
Trap messages are generated to report system events, as defined in RFC 1215. The system can
generate traps defined in the MIB that it supports.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350-28 and is the answer not in the manual?

Cisco SG350-28 Specifications

General IconGeneral
ModelSG350-28
CategorySwitch
Switching Capacity56 Gbps
LayerLayer 3
Power SupplyInternal
Form FactorRack-mountable
Relative Humidity10% to 90% non-condensing
MAC Address Table Size16K entries
Power Dedicated to PoENot applicable
Dimensions (W x D x H)440 x 257 x 44 mm
Operating Temperature0°C to 45°C
Storage Temperature-20°C to 70°C
Power Consumption24W
Input Voltage100-240V AC, 50/60Hz
Jumbo Frame SupportSupported
Weight3.2 kg