Supported Power Cords and Plugs 
Each power supply has a separate power cord. Standard power cords or jumper power cords are available 
for connection to a power distribution unit that has IEC 60320 C19 outlet receptacles. The jumper power 
cords, for use in racks, are available as an optional alternative to the standard power cords. For more 
information, contact Cisco technical support.
The standard power cords have an IEC C19 connector on the end that plugs into the Power Distribution 
Unit (PDU), which is located in the bottom slot at the rear of the chassis. The optional jumper power 
cords have an IEC C19 connector on the end that plugs into the chassis’ PDU and an IEC C20 connector 
on the end that plugs into an IEC C19 outlet receptacle.
Note Only the approved power cords or jumper power cords provided with the server are supported.
Table B-1 lists the power cords for the server power supplies 
Ta b l e  B-1 Supported Power Cords for the Server 
Description
Length
Power Cord Reference 
Illustration
Feet Meters
SFS-250V-10A-AR
Power Cord, 250 VAC 10 A IRAM 2073 Plug 
Argentina 
8.2 2.5 Figure B-2
CAB-9K10A-AU
250 VAC 10 A 3112 Plug, 
Australia 
8.2 2.5 Figure B-3
SFS-250V-10A-CN
Power Cord, 250 VAC 10 A GB 2009 Plug
China
8.2 2.5 Figure B-4
CAB-9K10A-EU
Power Cord, 250 VAC 10 A M 2511 Plug
Europe
8.2 2.5 Figure B-5
SFS-250V-10A-ID
Power Cord, 250 VAC 16A EL-208 Plug
South Africa, United Arab Emirates, India
8.2 2.5 Figure B-6
SFS-250V-10A-IS
Power Cord, 250 VAC 10 A SI32 Plug 
Israel 
8.2 2.5 Figure B-7
CAB-9K10A-IT
Power Cord, 250 VAC 10 A CEI 23-16 Plug 
Italy 
8.2 2.5 Figure B-8
CAB-9K10A-SW
Power Cord, 250 VAC 10 A MP232 Plug 
Switzerland 
8.2 2.5 Figure B-9