SM-A20758-A/3 3. USAGE
50 2020-10-06
Preset input
Switch the set pressure by specifying eight set pressures and using the three bits of the Process Data
OUT.
Ex.) To control the set pressure (0, 50, 100, 150, 200, 300, 400 or 500 kPa) with preset input Select
Preset Mode for "Input setting".
P1: 0 kPa, P2: 50 kPa, P3: 100 kPa, P4: 150 kPa
P5: 200 kPa, P6: 300 kPa, P7: 400 kPa, P8: 500 kPa
Make the above settings. When a signal is input with the Process Data OUT, the pressure is
switched to the set pressure stored in memory.
How to set preset input (by key operation)
Set "Input setting" and enter set pressures for "Preset memory" P1 to P8 by key operation.
For the setting method by key operation, refer to pages 37 and 38.
How to set preset input (using IO-Link communication)
[Parameter setting]
Input signal setting
Write "1: Preset Mode" to "Index:0x010F (Input
setting)".
Setting preset memory 1 to 8
Write set pressures to "Indexes: 0x0110 to 0x0117
(Preset memory 1 to 8)".
The set pressure shall be entered in 4 digits. When you do not use IODD, you do not need to
enter a decimal point; when you use IODD, you must include a decimal point.
Do not enter a value outside the allowable range. User's programs should control the pressure
so that it is within the allowable range for each model.
Index
Sub
Index
Item
Value
0x010F
0
Input setting
0: Normal Mode
1: Preset Mode
2: Direct Mode
0x0110
0
Preset memory 1
Refer to "Set
pressure
range for
each model
and unit"
-
-
-
0x0117
0
Preset memory 8
Parameter and Command