EasyManua.ls Logo

CKD EVD-3000 Series - 1.5.4 Process data IN

Default Icon
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SM-A20758-A/3 1. PRODUCT OVERVIEW
19 2020-10-06
Process data IN
PD
PD0
PD1
Bit
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
MSB
LSB
Data Name
Set Value for pressure
Data Range
2byte
Format
UInteger16
PD
PD2
PD3
Bit
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
MSB
LSB
Data Name
Control pressure
Data Range
2byte
Format
UInteger16
PD
PD4
PD5
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Data Name
Error
Warning
Normal
Operation
-
-
-
Switch
output
MSB
LSB
Input
Select
-
Start
/Stop
2
1
Error Code
Data Range
True/False
0 to 15
0 to 2
-
True/False
Format
Boolean
UInteger4
UInteger2
-
Boolean

Table of Contents

Other manuals for CKD EVD-3000 Series

Related product manuals