SM-A20758-A/3 3. USAGE
32 2020-10-06
3. USAGE
CAUTION
Create a program and control circuit that ignores signals for approximately two seconds
immediately after energized.
Pressure control will not operate for approximately two seconds immediately after energized for
self-diagnosis.
Stop the device before changing the set output value.
Control system devices may operate unintentionally.
Release the key lock before changing settings.
Checking the Set Value (RUN Mode)
Input signal type setting
The F1 screen shows the input signal type and its set value.
The current input specification setting, pressure value and unit are displayed alternately.
Input signal type symbol
Contents
IO-Link communication 16bit input
Input of 16bit using Process Data OUT
Preset memory input
Input of 3bit using Process Data OUT
Displays the selected preset no.
Direct memory input
Input signal type
Set unit (KPa)
or
(psi)
(Bar)
Pressure display
or
Unit change available
~