SM-A20758-A/3 3. USAGE
51 2020-10-06
[Operation]
Process Data OUT
Setting active state (pressure controlled state)
Set the "Start/Stop" bit of the Process Data OUT to "1" to
create an active state. Control is performed at the
pressure stored in the preset memory corresponding to
the preset memory number.
Switching preset memory
The preset memory number can be switched according
to the "Preset" setting of the Process Data OUT. Entering
the 3 bits of the "Preset" according to the right table
allows you to switch to any of the set pressures stored in
the memory areas.
[Confirmation]
Process Data IN
The controlled pressure, start/stop status, input setting, and set pressure can be checked with the
Process Data IN.
Check the current set pressure with the "Set Value for pressure" in Process Data IN.
When the "Start/Stop" bit of the Process Data IN is set to "0" (Stop) and the "Input setting" is
not set to "1" (Preset Mode), the pressure is not controlled even after the "Preset" bit of the
Process Data OUT is switched.
PD
PD0
PD1
Bit
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
MSB
LSB
Data name
Set pressure
PD
PD2
PD3
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Data name
Unused
Preset
Unused
Start/Stop
3
2
1
"Preset" of Process Data OUT
Preset
memory
number
Bit 3
Bit 2
Bit 1
0
0
0
P1
0
0
1
P2
0
1
0
P3
0
1
1
P4
1
0
0
P5
1
0
1
P6
1
1
0
P7
1
1
1
P8
PD
PD0
PD1
Bit
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
MSB
LSB
Data name
Set pressure: The set pressure in the preset memory area corresponding to the specified number is displayed.
PD
PD2
PD3
Bit
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
MSB
LSB
Data name
Controlled pressure: EVD’s controlled pressure value is displayed here.
PD
PD4
PD5
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
-
-
-
-
-
-
-
-
-
-
-
-
0
1
-
1
Data name
Error
Warning
-
-
-
Switch
output
MSB
LSB
Input setting
-
Start/Stop
2
1
Error code