CKD SHD3025 - No Load Operation; Alarm Outlet

Default Icon
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
<SM-13024-A>
9
6)
ThesensorusedfortheG-typeisdifferentfromthatfortheM-type.
G-type
Temperature and humidity
sensor
Inparticular,theaccuracybecomesverybad
in the low dew point area (standard use).
Troublemayoccurinenergysavingoperation
by the case at the time of -40 ℃
specification.
Approximately+20
Cto
-
45
C
-type
Dewpointmeter
Themeasurementcanbeperformedwith
ahighaccuracyintheentirearea(±2 C
atdewpoint>-60 C)
+20℃ to-80℃
7)
Whentheenergysavingoperationisstarted,theECOlampislit,thepurgeisstopped,and
both vessels A and B are pressurized. The desiccant vessels are not switched and the
currentstatusiskept. (Theswitchingtimeisextended.)Whentheoperationisreturnedto
thenormaloperation,theECOlampgoesoffandthepurgeisrestarted.
8) Werecommendyoutomakeittheenergy-savingsettingdewpointinthesamenumerical
valueastherateddewpointselectedinmodel.Becareful,sincethedisposalofreducing
inletflowisneededincasethesettingdewpointischangedmoreintoalowdewpointside.
9) If24hoursafteroperationstartpass,energysavingratecanbedisplayedtodisplaypart
asnumericalvaluebypushingSTARTbuttonduringoperation.Useformanagementevery
day.Inaddition,becareful,sinceitcannotbeusedduringstop.
ENERGYSAVINGRATE=1-(PURGETIMEINENERGYSAVING)/(PURGETIMEINRATING)
5-4Noloadoperation
After purchase, or when there is little air consumption by the side of secondary, and
energy-savingoperationhasnotbeencarriedout,thesurfaceoutsidethedesiccantvessels
may get cold and may dew or freeze. This is a phenomenon which happens at the time of
desiccant reproduction, and is not alarm. If you put in energy-saving equipment, dew
condensationwillstopbeingabletooccureasily.
5-5Alarmoutlet
Thisproductisequippedstandardlywiththealarmsignaloutput.Inaddition,whenthepower
supplyisnoton,itshowsyouasalarm.
1) Alarmsensor
Disconnectionofasensoretc.showsyouwithanon-voltagecontactoutput(alarmtime)
anddisplayingthedewpointdisplaypartofanoperationpanelas"A01"afterstarting,
However,mainpartdoesnotstop.Itwillbecanceledifitreturnstonormal.Inaddition,
afterpushingSTOPinthestateoftheabnormalitiesinasensor(A01display),evenifit
pushes START, it does not start. It will start, if START is pushed after canceling
abnormalities or making it reset (it is 2-second length aggressiveness about START).
(Sinceresetcannotdoatthetimeofremoteoperation,performreset,oncechangingto
localoperation.)