<SM-13024-A>
9
6)
ThesensorusedfortheG-typeisdifferentfromthatfortheM-type.
G-type
Temperature and humidity
sensor
Inparticular,theaccuracybecomesverybad
in the low dew point area (standard use).
Troublemayoccurinenergysavingoperation
by the case at the time of -40 ℃
specification.
M
-type
Themeasurementcanbeperformedwith
ahighaccuracyintheentirearea(±2 C
atdewpoint>-60 C)
+20℃ to-80℃
7)
Whentheenergysavingoperationisstarted,theECOlampislit,thepurgeisstopped,and
both vessels A and B are pressurized. The desiccant vessels are not switched and the
currentstatusiskept. (Theswitchingtimeisextended.)Whentheoperationisreturnedto
thenormaloperation,theECOlampgoesoffandthepurgeisrestarted.
8) Werecommendyoutomakeittheenergy-savingsettingdewpointinthesamenumerical
valueastherateddewpointselectedinmodel.Becareful,sincethedisposalofreducing
inletflowisneededincasethesettingdewpointischangedmoreintoalowdewpointside.
9) If24hoursafteroperationstartpass,energysavingratecanbedisplayedtodisplaypart
asnumericalvaluebypushingSTARTbuttonduringoperation.Useformanagementevery
day.Inaddition,becareful,sinceitcannotbeusedduringstop.
ENERGYSAVINGRATE=1-(PURGETIMEINENERGYSAVING)/(PURGETIMEINRATING)
5-4Noloadoperation
After purchase, or when there is little air consumption by the side of secondary, and
energy-savingoperationhasnotbeencarriedout,thesurfaceoutsidethedesiccantvessels
may get cold and may dew or freeze. This is a phenomenon which happens at the time of
desiccant reproduction, and is not alarm. If you put in energy-saving equipment, dew
condensationwillstopbeingabletooccureasily.
5-5Alarmoutlet
Thisproductisequippedstandardlywiththealarmsignaloutput.Inaddition,whenthepower
supplyisnoton,itshowsyouasalarm.
1) Alarmsensor
① Disconnectionofasensoretc.showsyouwithanon-voltagecontactoutput(alarmtime)
anddisplayingthedewpointdisplaypartofanoperationpanelas"A01"afterstarting,
However,mainpartdoesnotstop.Itwillbecanceledifitreturnstonormal.Inaddition,
afterpushingSTOPinthestateoftheabnormalitiesinasensor(A01display),evenifit
pushes START, it does not start. It will start, if START is pushed after canceling
abnormalities or making it reset (it is 2-second length aggressiveness about START).
(Sinceresetcannotdoatthetimeofremoteoperation,performreset,oncechangingto
localoperation.)