<SM-13024-A>
5
Filter
Valve
Totheend
Fromthecompressor
4-3Installationplace
1)
Installthisproductinaplacewheretheambient
temperatureis0to40
C.
2) Installthisproductonaleveledfloorwhereany
vibrationdoesnotexist.
Whenafloorisnotlevel,distortionmayarisefor
aproductandfaultmayoccur.
3)
Ifthefoundationoftheinstallationplaceisweak,
carryoutthefoundationconstructionwork.
4)
Keep the following space for the maintenance
andinspectionwork.(600mmormore).
5)
Securethisproductfirmlyusinganchorboltssothattheproductis notlaiddownifan
earthquakeorasuddenimpactoccurs.
6)
Do not install this product in an outdoor place. This product does not have any
water-proofstructure.Ifrainwaterissplashedontotheelectricalsystem,earthleakageor
fireaccidentmayoccur.
7)
Donotinstallthisproductinaplacewhereitisnotexposedtothedirectsunlight,particle
dust, or heating element, or any corrosive gas, explosive gas, flammable gas, or
combustiblematerialdoesnotexist.
*Breakdown, explosion, or fire may result.
8)
Compressedairshouldnotflowbackwardsforfilterprotection.
9) Waterdropmaydispersefromtheexhaustsilencerofdryerrarelyundertheinfluenceof
ambienttemperatureetc.Installdrainpanetc.inthatcase.
10) Donotmixwaterdropinairinlet.Performancenotonlygetsworse,butitbecomesthe
causeoffailure.Whenthereisapossibilitythatwaterdropmaymix,installaftercooleror
refrigeratedairdryerintheupstreamofthisequipment.
4-4Airpiping
1)
Alwaysstartthepipingworkaftercheckingtheairinletandoutlet.
2) AttachtheairfilterM-seriessuppliedwiththeproducttotheairinlet. Inaddition,when
thequalityofairflowinginisbad,attachanoptionalfilterbeforetheMseriesconcerned.
3) AttachtheairfilterP-seriessuppliedwiththeproducttotheairoutlet.Inaddition,whena
visitor'squalityofdemandairishigh,attachanoptionalfilterafterthePseriesconcerned.
4) Sincemoisturemaycondensewithinpiping,thedistancebetweenairfilterM seriesand
theentranceofmainpartissetto1morlessasastandard.
5)
MakethedistancebetweentheairfilterM-seriesandtheinletofthemainbodyasshort
aspossiblesincewatercontentsmaybecondensedinsidethepiping.
6)
If the flow inside the piping cannot be shut down
whenstartingthemaintenanceandinspectionwork
ofthemainbody,installabypasscircuithavingthe
stopvalve.
7)
Carefullydesignthepipingroutesothattheweight
ofthepipingisnotappliedtothemainbody.