<SM-13024-A>
17
Display
[ALARM]lampislit.
A01
Wiringofthedewpointsensorisnot
connected.
Connectthewiringofthe dewpoint
sensor.
(A01putsoutthelight.)
A01
Dewpointsensorisfaulty. Replacethedewpointsensor.
(A01putsoutthelight.)
Blink Dewpointishigh. Lower the inlet air temperature and
inletairflow.
A01
Position of the DIP switch on the
rearofthecontrollerisincorrect.
ChangetheDIPswitchtoitsproper
position,andthenallcleariscarried
out.
「G-type」 「M-type」
A01
Connectorofboard(XP03,XP04)
notfittedin.
Itisfittedin.
(A01putsoutthelight.)
White powder particles
come out from the
silencer.
Powder particles sticking to the
desiccant, which is not in use, may
scatter.
It is correct. Powder particles are
produced when this product is
operated for the first time. This
symptom may disappear after the
product has been operated for a
while.
Watercomesoutfromthe
silencer.
Inletairtemperatureistoohigh. Lowertheinletair
temperature.
Autodrainofthefilterisbrokenand
waterdropsmayenterthedryer.
Repairtheautodrain.
Airflowistoohigh. Lower the air flow rate to its rated
level.
The dew point does not
fall.
Timeisrequiredinordertoreachthe
lowdewpoint.
The standard of time is indicated in
"5-1operation."
Dew is attached to a
desiccantvessel.
At the time of desorption, it is
because it gets cold and is not
unusual. There are especially few
amounts of secondary side
consumption, and it is the
phenomenon which is easy to set
while not putting in energy saving
equipment.
It will become difficult to set if
energysavingequipmentisputin.
Even if it puts in
energy-saving equipment,
itwillfallfromthesetting
dewpoint.
Since the desiccant is new
immediately after installation, the
dewpointwillfall.
Itisnotunusual.Ifyoucanusefora
while, it will become close to the
settingdewpoint.
Donotstart Both inlet valve shut when
pressuring it afterwards because it
haddoneSTRATwhenpressurewas
low.
Amanualvalveisopened.
Referto5-1-5)totheclause.
STRATbuttonisnotpushed. It is started pushing the STRAT
button.