<SM-13024-A>
25
No.
Partname
PartsNo.
Sketch
Numbers
Servicelifeof
maintenancepart
1year
orless
2yearor
less
3yearor
less
10
Inletvalveassembly
R
SHD-AFL-413334
SHD3025
SHD3045
SHD3075
1
○SHD-AFL-413336
SHD3100
SHD3125
1
SHD-AFL-413338
SHD3150
SHD3200
SHD3240
1
11
Inletvalveassembly
L
SHD-AFL-413335
SHD3025
SHD3045
SHD3075
1
○
SHD-AFL-413337
SHD3100
SHD3125
1
SHD-AFL-413339
SHD3150
SHD3200
SHD3240
1
12
Exhaustvalve
assembly
SHD-AFL-413340
SHD3025
SHD3045
SHD3075
1
○
SHD-AFL-413341
SHD3100
SHD3125
1
SHD-AFL-413342
SHD3150
SHD3200
SHD3240
1
13
Checkvalve
assembly
SHD-AFL-331853
2
○
14
Mantleassembly 1219-MANTLE-ASSY
Microalescermantlefor
dewpointsensor
1
○
Note
1. SinceSHD3075ormoremodelcorrespondstothesecondsortpressurevesselstructurestandard,
correspondencebythedesiccantvesselassemblycannotbeperformed.(Itbecomesvesselchange
andre-takinganexaminationisneeded.)
2. Desiccantexchangeservesaswhichmethodof1,2,and3.Itchoosesofavisitor.