CI Man u al Page 19
User Display Settings
General Operation
When the system is operating, one of ve displays may be
shown. Pressing NEXT will alternate between the displays. One
of the displays is always the current time of day. The second
display is one of the following: days remaining or volume
remaining. Days remaining is the number of days left before the
system goes through a regeneration cycle. Capacity remaining
is the cubic meters that will be treated before the system goes
through a regeneration cycle. The third display shows the current
treated water ow rate through the system. If 1.0 is selected
in Step 2CS, an “A” in front of the ow rate indicates that the
tank with the control valve on it is in service. If “b” is displayed,
the tank with the in/out head is in service. The fourth display
will show either dP or hold if the dP switch is closed. The fth
display shows the kg of salt remaining or ashes “SALT” ll
when the calculated kg of salt falls below a safety level. The fth
display will not appear if the valve is a WS2, set up as a lter or
if the Set Low Salt Warning is set to off (see last step in OEM
Softener System Setup). The user can scroll between the displays
as desired.
If the system has called for a regeneration that will occur at the
preset time of regeneration, the words REGEN TODAY will
appear on the display.
If a water meter is installed, the word “Softening” or “Filtering”
ashes on the display when water is being treated (i.e. water is
owing through the system).
or
REGEN TODAY will
Flash if a regeneration
is expected “Tonight.”
In Alternator Systems when a unit is waiting to initiate the rst cycle step of regeneration,
“REGEN Pndg” is displayed.
“STbY” is displayed in Alternator Systems when a valve is in Standby state.
“REGEN Pndg FILL RINSE” is displayed whenever a zero-capacity tank has transferred to
an off-line state and is currently waiting to initiate the second portion of a regeneration cycle.
Viewed only when Delayed Rinse and Fill is set to ON.