12
Instructions for installer - 9120-25533 - CEX9-U - 801042 - November 2012 v1.00
Note “Reinstallation“
If the appliance is to be re-commissioned under different installation conditions it may be necessary to alter the maximum power rating.
This should only be done by a competent installer.
To re-set the maximum power rating use a screwdriver to short circuit the two pins as shown in Fig.5.
This will reset all heater parameters to factory settings.
Value “88” will fl ash in the display panel until the maximum power rating has been selected.
9. Initial operation