15
Register COMMUNICATOR
®
s
The Communicator must be within 6 feet (1.83 meters) of the base station to enable registration.
1.  Be certain all headsets to be registered are turned OFF, and the base station power is ON.
2.  Place the headset on your head.
3.  Press the REG button on the front panel of the base station. The STATUS display will show a 
small “o” for open.
NOTE:  If you wait too long before going on to the next step, the base station will exit 
registration mode, requiring that you press the REG button again.
4.  Press and hold the ISO button on the Communicator while you press and release the 
Power button (PWR). After power up, release the ISO button. The Communicator will 
enter Registration mode.
On Belt Packs, the two power lights at the corners near the A and B buttons will 
begin blinking red, and then they will blink green two or three times then turn off.  
Note: There may be a short delay.
On All-In-One Headsets, the power/mode lights located at the end of the 
microphone boom and on the side of the unit near the A button will blink.  
Note: There may be a short delay.
If registration is successfully completed:
 h A voice prompt in the headset will say “Battery level, begin registration…”.
 h After a delay of about 15 seconds, the STATUS display will show the ID number assigned to the 
Communicator for about 10 seconds.
NOTE: ID numbers are assigned sequentially 0 through 9, then A, b, C, d and E.
 h The power light on the Communicator will display steady green.
If registration failed:
 h A voice message in the headset will say “Battery level, begin registration…” Both lights 
on the Belt Pack will be blinking red, and there may be a delay of up to 90 seconds 
before you hear “Registration failed.”
 h Press the RESET button at the lower-left corner of the base station with a pen or similar 
pointed object. When the STATUS display becomes blank, press the REG button 
and register the Communicator again. If registration fails again, call your dealer for 
assistance.
If you try to register more than 15 Communicators:
 h An “F” will appear on the STATUS display on the base station and you will hear “Registration failed” 
in the headset.
 h Clear all current registrations by pressing the CLR/BND button and the RESET button at the same 
time. To press the RESET button, insert a pen or similar pointed object into the RESET hole at the 
lower-left corner of the base station front panel. Continue holding the CLR/BND button after you 
release the RESET button, until the clear code “c” (lower case) appears on the STATUS display.
 h Register all active Communicators, one at a time. Previously registered Communicators must be 